Torque — Displays the Output Torque as a percentage of the rated capacity of the H9 ASD. Torque Reference — Displays the Torque Reference as a percentage.

Torque Current — Displays the torque-producing current value.

Excitation Current — Displays the current value required to produce the excitation field. PID Feedback — Provides a status of the PID Real Time Feedback in Hz.

Input Power — Displays the Input Power in Kilowatts (Kw).

Output Power — Displays the Output Power in Kilowatts (Kw).

Pattern Group Number Displays the active Pattern Run Group Number. Pattern Group Cycle Displays the cycle number of the active Pattern Run Group.

Pattern Group Preset Displays the active Preset Speed being run of the active Pattern Run Group.

Pattern Time Displays the remaining time for the active Pattern Run Group.

RR— Displays the RR input value as a percentage of the full range of the RR value (potentiometer input).

*V/I — Displays the V/I input setting as a percentage of the full range of the V/I value.

Note: The isolated V/I input terminal may receive Current or Voltage to control the output speed or the output torque. The input signal type must be selected at SW301 on the Terminal Board.

The V input setting of SW301 is used for the 0 – 10 VDC analog input signal and the I input setting of SW301 is used for the 0 – 20 mA analog input signal. Either may be used as a frequency or torque command source. See parameter F201 for more information on the setup of this terminal.

On the LCD display the V/I terminal is listed as the VI/II terminal (the additional letter I is used to indicate “input.”).

RX — Displays the RX input setting as a percentage of the full range of the RX value (-10 to +10 VDC input).

RX2 Option (AI1) — Displays the RX2 input setting as a percentage of the full range of the RX2 value.

Note: The RX2 function is available on the Expansion IO Card Option 1 option board (P/N ETB003Z) only.

Trip Code Displays None if there are no errors, or displays one of the associated Fault Codes listed in Table 14 on page 250 if there is an active Fault (e.g., E = Emergency Off).

Past Trip #1 This function records and displays the last trip incurred. Subsequent trips will replace Past Trip #1. As trip records are replaced they are shifted to the next level of the Past Trip locations until being deleted (i.e., Past Trip #1 is moved to Past Trip #2 and then to #3 until being shifted out of #4). Once shifted out of Past Trip #4 the record is deleted. If no trips have occurred since the last reset, None is displayed for each trip record.

Past Trip #2 Past Trip information.

Past Trip #3 Past Trip information.

Past Trip #4 Past Trip information.

Note: An improper H9 ASD setup may cause some trips — reset the H9 ASD to the Factory Default settings before pursuing a systemic malfunction (Program Utilities Type Reset Reset to Factory Settings).