F552 |
| F560 | |
|
|
| |
Speed 13 Operation Time | Direct Access Number — | F552 | |
Program ⇒ Pattern Run ⇒ Operation Time | Parameter Type — Numerical | ||
This parameter sets the | Factory Default — 5.0 |
| |
Changeable During Run — Yes | |||
This time is effective when used with Group Speeds and | |||
Minimum — 0.1 |
| ||
If the |
| ||
Maximum — 6000.0 |
| ||
Restart function will be subtracted from the Operation Time setting; resulting |
| ||
Units — F520 Setting |
| ||
in a shorter run time. |
| ||
|
|
| |
Speed 14 Operation Time | Direct Access Number — | F553 | |
Program ⇒ Pattern Run ⇒ Operation Time | Parameter Type — Numerical | ||
This parameter sets the | Factory Default — 5.0 |
| |
Changeable During Run — Yes | |||
This time is effective when used with Group Speeds and | |||
Minimum — 0.1 |
| ||
If the |
| ||
Maximum — 6000.0 |
| ||
Restart function will be subtracted from the Operation Time setting; resulting |
| ||
Units — F520 Setting |
| ||
in a shorter run time. |
| ||
|
|
| |
Speed 15 Operation Time | Direct Access Number — | F554 | |
Program ⇒ Pattern Run ⇒ Operation Time | Parameter Type — Numerical | ||
This parameter sets the | Factory Default — 5.0 |
| |
Changeable During Run — Yes | |||
This time is effective when used with Group Speeds and | |||
Minimum — 0.1 |
| ||
If the |
| ||
Maximum — 6000.0 |
| ||
Restart function will be subtracted from the Operation Time setting; resulting |
| ||
Units — F520 Setting |
| ||
in a shorter run time. |
| ||
|
|
| |
Preset Speed Operation Mode | Direct Access Number — | F560 | |
Program ⇒ Pattern Run ⇒ Operation Mode | Parameter Type — Selection List | ||
| Factory Default — Disabled |
|
This parameter is used to set the Preset Speed operating mode.
Changeable During Run — No
Select Disabled at this parameter to use the speed command only for Preset Speed operation.
Select Enabled at this parameter to apply the control settings of F561 – F575 to the associated Preset Speed while operating in the Preset Speed mode.
Settings:
0 — Disabled (Preset Speed Only)
1 — Enabled (Full Preset Speed Mode)
H9 ASD Installation and Operation Manual | 179 |