![](/images/new-backgrounds/1203794/203794471x1.webp)
F959 | F962 | ||
|
| ||
Analog Input Function Target 11 | Direct Access Number — F959 | ||
Program ⇒ My Function ⇒ My Function Analog | Parameter Type — Selection List | ||
This parameter plays a role in the setup of the My Function feature by | Factory Default — 0 (Disabled) | ||
Changeable During Run — Yes | |||
selecting the functionality of the programmable Analog Input Function Target | |||
| |||
11 terminal. |
| ||
The function selected at F961 may be adjusted using the input analog control |
| ||
signal selected here. |
| ||
Settings: |
| ||
0 | — Disabled (None) |
| |
1 | — V/I |
| |
2 | — RR |
| |
3 | — RX |
|
4— Optional RX2+, RX2-
5— Optional V/I
Analog Function Assigned Object 11 | Direct Access Number — F961 | ||
Program ⇒ My Function ⇒ My Function Analog | Parameter Type — Selection List | ||
This parameter plays a role in the setup of the My Function feature by | Factory Default — 0 (Disabled) | ||
Changeable During Run — Yes | |||
selecting the functionality to which the adjustment of F959 is applied. | |||
| |||
Settings: |
| ||
0 | — Disabled (None) |
| |
1 | — Acceleration Rate |
| |
2 | — Upper Limit Frequency |
| |
3 | — Acceleration Multiplication Factor |
| |
4 | — Deceleration Multiplication Factor |
| |
5 | — Manual Torque Boost |
|
6— Over Current Stall (F601)
7— Thermal Protection
8— Speed Loop P Gain (F460)
9— Drooping Gain (F320)
10— PID P Gain (F362)
See the My Function Instruction Manual (P/N 58692) for a complete description of the setup requirements and operational information of the Analog Function Assigned Object parameter.
Analog Input Function Target 21 | Direct Access Number — F962 | ||
Program ⇒ My Function ⇒ My Function Analog | Parameter Type — Selection List | ||
This parameter plays a role in the setup of the My Function feature by | Factory Default — 0 (Disabled) | ||
Changeable During Run — Yes | |||
selecting the functionality of the programmable Analog Input Function Target | |||
| |||
21 terminal. |
| ||
The function selected at F964 may be adjusted using the input analog control |
| ||
signal selected here. |
| ||
Settings: |
| ||
0 | — Disabled (None) |
| |
1 | — V/I |
| |
2 | — RR |
| |
3 | — RX |
|
4— Optional RX2+, RX2-
5— Optional V/I
228 | H9 ASD Installation and Operation Manual |