My Function Percent Data 3
Program ⇒ My Function ⇒ My Function Data
This parameter is used to set the trigger threshold level of the analog signal of the My Function Percent Data 3.
The analog signal is selected using the Input Setting number from Table 8 on pg. 241.
Direct Access Number — F920
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Percent Data 4
Program ⇒ My Function ⇒ My Function Data
This parameter is used to set the trigger threshold level of the analog signal of the My Function Percent Data 4.
The analog signal is selected using the Input Setting number from Table 8 on pg. 241.
Direct Access Number — F921
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Percent Data 5
Program ⇒ My Function ⇒ My Function Data
This parameter is used to set the trigger threshold level of the analog signal of the My Function Percent Data 5.
The analog signal is selected using the Input Setting number from Table 8 on pg. 241.
Direct Access Number — F922
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Frequency Data 1
Program ⇒ My Function ⇒ My Function Data
This parameter is used to set the trigger threshold level of the analog signal of the My Function Frequency Data 1.
The analog signal is selected using the Input Setting number from Table 8 on pg. 241.
Direct Access Number — F923
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Frequency Data 2
Program ⇒ My Function ⇒ My Function Data
This parameter is used to set the trigger threshold level of the analog signal of the My Function Frequency Data 2.
The analog signal is selected using the Input Setting number from Table 8 on pg. 241.
Direct Access Number — F924
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
My Function Frequency Data 3
Program ⇒ My Function ⇒ My Function Data
This parameter is used to set the trigger threshold level of the analog signal of the My Function Frequency Data 1.
The analog signal is selected using the Input Setting number from Table 8 on pg. 241.
Direct Access Number — F925
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 200.00
Units — %
220 | H9 ASD Installation and Operation Manual |