My Function Percent Data 3

Program My Function My Function Data

This parameter is used to set the trigger threshold level of the analog signal of the My Function Percent Data 3.

The analog signal is selected using the Input Setting number from Table 8 on pg. 241.

Direct Access Number — F920

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 200.00

Units — %

My Function Percent Data 4

Program My Function My Function Data

This parameter is used to set the trigger threshold level of the analog signal of the My Function Percent Data 4.

The analog signal is selected using the Input Setting number from Table 8 on pg. 241.

Direct Access Number — F921

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 200.00

Units — %

My Function Percent Data 5

Program My Function My Function Data

This parameter is used to set the trigger threshold level of the analog signal of the My Function Percent Data 5.

The analog signal is selected using the Input Setting number from Table 8 on pg. 241.

Direct Access Number — F922

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 200.00

Units — %

My Function Frequency Data 1

Program My Function My Function Data

This parameter is used to set the trigger threshold level of the analog signal of the My Function Frequency Data 1.

The analog signal is selected using the Input Setting number from Table 8 on pg. 241.

Direct Access Number — F923

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 200.00

Units — %

My Function Frequency Data 2

Program My Function My Function Data

This parameter is used to set the trigger threshold level of the analog signal of the My Function Frequency Data 2.

The analog signal is selected using the Input Setting number from Table 8 on pg. 241.

Direct Access Number — F924

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 200.00

Units — %

My Function Frequency Data 3

Program My Function My Function Data

This parameter is used to set the trigger threshold level of the analog signal of the My Function Frequency Data 1.

The analog signal is selected using the Input Setting number from Table 8 on pg. 241.

Direct Access Number — F925

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 200.00

Units — %