F540

 

F545

 

 

 

Speed 1 Operation Time

Direct Access Number —

F540

Program Pattern Run Operation Time

Parameter Type — Numerical

This parameter sets the run-time for Preset Speed #1.

Factory Default — 5.0

 

Changeable During Run — Yes

This time is effective when used with Group Speeds and non-Group Speeds.

Minimum — 0.1

 

If the Auto-Restartfunction is activated, the search time required for the Auto-

 

Maximum — 6000.0

 

Restart function will be subtracted from the Operation Time setting; resulting

 

Units — F520 Setting

 

in a shorter run time.

 

 

 

 

Speed 2 Operation Time

Direct Access Number —

F541

Program Pattern Run Operation Time

Parameter Type — Numerical

This parameter sets the run-time for Preset Speed #2.

Factory Default — 5.0

 

Changeable During Run — Yes

This time is effective when used with Group Speeds and non-Group Speeds.

Minimum — 0.1

 

If the Auto-Restartfunction is activated, the search time required for the Auto-

 

Maximum — 6000.0

 

Restart function will be subtracted from the Operation Time setting; resulting

 

Units — F520 Setting

 

in a shorter run time.

 

 

 

 

Speed 3 Operation Time

Direct Access Number —

F542

Program Pattern Run Operation Time

Parameter Type — Numerical

This parameter sets the run-time for Preset Speed #3.

Factory Default — 5.0

 

Changeable During Run — Yes

This time is effective when used with Group Speeds and non-Group Speeds.

Minimum — 0.1

 

If the Auto-Restartfunction is activated, the search time required for the Auto-

 

Maximum — 6000.0

 

Restart function will be subtracted from the Operation Time setting; resulting

 

Units — F520 Setting

 

in a shorter run time.

 

 

 

 

Speed 4 Operation Time

Direct Access Number —

F543

Program Pattern Run Operation Time

Parameter Type — Numerical

This parameter sets the run-time for Preset Speed #4.

Factory Default — 5.0

 

Changeable During Run — Yes

This time is effective when used with Group Speeds and non-Group Speeds.

Minimum — 0.1

 

If the Auto-Restartfunction is activated, the search time required for the Auto-

 

Maximum — 6000.0

 

Restart function will be subtracted from the Operation Time setting; resulting

 

Units — F520 Setting

 

in a shorter run time.

 

 

 

 

Speed 5 Operation Time

Direct Access Number —

F544

Program Pattern Run Operation Time

Parameter Type — Numerical

This parameter sets the run-time for Preset Speed #5.

Factory Default — 5.0

 

Changeable During Run — Yes

This time is effective when used with Group Speeds and non-Group Speeds.

Minimum — 0.1

 

If the Auto-Restartfunction is activated, the search time required for the Auto-

 

Maximum — 6000.0

 

Restart function will be subtracted from the Operation Time setting; resulting

 

Units — F520 Setting

 

in a shorter run time.

 

 

 

 

Speed 6 Operation Time

Direct Access Number —

F545

Program Pattern Run Operation Time

Parameter Type — Numerical

This parameter sets the run-time for Preset Speed #6.

Factory Default — 5.0

 

Changeable During Run — Yes

This time is effective when used with Group Speeds and non-Group Speeds.

Minimum — 0.1

 

If the Auto-Restartfunction is activated, the search time required for the Auto-

 

Maximum — 6000.0

 

Restart function will be subtracted from the Operation Time setting; resulting

 

Units — F520 Setting

 

in a shorter run time.

 

H9 ASD Installation and Operation Manual

177

Page 185
Image 185
Toshiba H9 operation manual F540 F545