Toshiba H9 operation manual F004, Command Mode

Models: H9

1 289
Download 289 pages 12.38 Kb
Page 85
Image 85

F003

 

F004

 

 

 

 

Command Mode

Direct Access Number — F003

 

Program Fundamental Standard Mode Selection

Parameter Type — Selection List

 

The Command Mode Selection establishes the source of the command input

Factory Default — Terminal Block

 

Changeable During Run — No

 

for the ASD. Command inputs include Run, Stop, Forward, etc. The Override

 

 

 

feature may supersede the Command Mode Selection setting (see Command

 

 

Mode and Frequency Mode Control on pg. 36).

 

 

Settings:

 

0

— Terminal Block

 

1

— Not Used

 

2

— EOI Keypad

 

3

— RS485

 

4

— Communication Option Board

 

 

 

 

 

Frequency Mode 1

Direct Access Number — F004

 

Program Fundamental Standard Mode Selection

Parameter Type — Selection List

 

 

 

Factory Default — RR

The Frequency Mode 1 setting establishes the source of the frequency-control

input for the ASD. The Frequency Mode 2 setting or the Override feature may

Changeable During Run — No

 

supersede the Frequency Mode 1 setting (see Command Mode and Frequency

 

Mode Control on pg. 36 and F200 for more information on this setting).

 

Note: Only Bolded items from the Settings list below may be placed in the Override mode. See the section titled Command Mode and Frequency Mode Control on pg. 36 for more information on the Override feature.

Settings:

1 — V/I

2 — RR

3 — RX

5 — EOI Keypad

6 — RS485

7 — Communication Option Board

8 — RX2 Option (AI1)

9 — Option V/I

10 — UP/DOWN Frequency

11 — Pulse Input (option)

12 — Pulse Input (motor CPU)

13 — Binary/BCD Input (option)

H9 ASD Installation and Operation Manual

77

Page 85
Image 85
Toshiba H9 operation manual F004, Command Mode