Monitor Output Function 21

Program My Function My Function Monitor

This parameter plays a role in the setup of the My Function feature by establishing the function that is to be recorded and output as the Peak, Minimum, or Average value as selected at parameter F968.

Select the Monitor Display Input Setting number from Table 10 on pg. 243 to output the corresponding function.

Use the Communication Number if operating using communications.

See the My Function Instruction Manual (P/N 58692) for a complete description of the setup requirements and operational information of the Monitor Output Function parameter.

Direct Access Number — F967

Parameter Type — Selection List

Factory Default — 2000

Changeable During Run — Yes

Monitor Output Function Command 21

Program My Function My Function Monitor

This parameter plays a role in the setup of the My Function feature by allowing the user to select the Peak, Minimum, or Normal (Avg.) value of the parameter F967 selection to be recorded and output as a monitored function.

Settings:

0 — Normal

1 — Peak

2 — Minimum

Direct Access Number — F968

Parameter Type — Selection List

Factory Default — Normal

Changeable During Run — Yes

See the My Function Instruction Manual (P/N 58692) for a complete description of the setup requirements and operational information of the Monitor Output Function parameter.

Monitor Output Function 31

Direct Access Number — F969

Program My Function My Function Monitor

Parameter Type — Selection List

This parameter plays a role in the setup of the My Function feature by

Factory Default — 2000

Changeable During Run — Yes

establishing the function that is to be recorded and output as the Peak,

 

Minimum, or Average value as selected at parameter F970.

 

Select the Monitor Display Input Setting number from Table 10 on pg. 243 to

 

output the corresponding function.

 

Use the Communication Number if operating using communications.

 

See the My Function Instruction Manual (P/N 58692) for a complete

 

description of the setup requirements and operational information of the

 

Monitor Output Function parameter.

 