F342

F346

 

 

Torque Bias Input Selection

Direct Access Number — F342

Program Torque Torque Control

Parameter Type — Selection List

Once enabled at parameter F341, this parameter sets the source of the input

Factory Default — Disabled

Changeable During Run — Yes

signal that will set the torque level used for to provide the Braking Mode

 

Selection function of parameter F341.

 

Settings:

0 — Disabled

1 — V/I

2 — RR

3 — RX

4 — Panel Keypad

5 — RS485 2-Wire

6 — RS485 4-Wire

7 — Communication Option Board

8 — RX2 Option (AI1)

Panel Torque Bias

Direct Access Number — F343

Program Torque Torque Control

Parameter Type — Numerical

Once enabled at parameter F341, this parameter establishes the torque bias

Factory Default — 100.00

Changeable During Run — Yes

setting to which the setting of F342 will either add to or subtract from to

 

produce the final torque value used to carry out the Braking Mode Selection

Minimum — -250.00

function of parameter F341.

Maximum — +250.00

 

 

Units — %

Panel Torque Gain

Program Torque Torque Control

Once enabled at parameter F341, this parameter sets the sensitivity of the torque control source selected at F342 for the Braking Mode Selection function of parameter F341.

Direct Access Number — F344

Parameter Type — Numerical

Factory Default — 100.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 100.00

Units — %

Release Time

Program Torque Torque Control

Once enabled at parameter F341, this parameter sets the time that the brake will hold after the requirements of the Braking Mode Selection function of parameter F341 have been met.

Direct Access Number — F345

Parameter Type — Numerical

Factory Default — 0.05

Changeable During Run — Yes

Minimum — 0.00

Maximum — 2.50

Units — Seconds

Creeping Frequency

Program Torque Torque Control

Once enabled at parameter F341, and while running, upon receiving a Stop command this parameter sets an output frequency to be provided for the duration of the time setting of parameter F347.

Direct Access Number — F346

Parameter Type — Numerical

Factory Default — 3.00

Changeable During Run — Yes

Minimum — F240 Setting

Maximum — 20.0

Units — Hz