104 H9 ASD Installation and Operation Manual

V/f Five-Point Setti ng Frequency 5

Program Special V/f Five-Point Setting
The Custom V/f Five-Point Setting Frequenc y 5 sets the frequency to be
associated with the voltage setting of parameter F199 (V/f Five-Point Setting
Volta ge 5).
See F190 and F191 for additional information on this setting.
Direct Access Number — F198
Parameter Type — Numeri cal
Factory Default — 0.00
Changeable During Run — No
Minimum — 0.00
Maximum — Max. Freq. (F011)
Units — Hz

V/f Five-Point Setti ng Voltage 5

Program Special V/f Five-Point Setting
The V/f Five-Point Setting Voltage 5 establishes the output voltage level that
is to be associated with the frequenc y setting of F198 (V/f Five-Point Setting
Frequency 5).
The F701 parameter setting will dete rmine if the selection for this parameter
appears in the form of a Voltage (V) or as a Percentage (%) of the ASD rating .
The default setting is %.
See F190 and F191 for additional information on this setting.
Direct Access Number — F199
Parameter Type — Numeri cal
Factory Default — 0.0
Changeable During Run — No
Minimum — 0.0
Maximum — 100.0
Units — V or % (F701)

Frequency Priority Selection

Program Fundamental Standard Mode Selection
Either Frequency Mode 1 or Frequency Mode 2 may control the output
frequency of the ASD. This parameter determines which of the two will control
the output frequency and the conditions in which control will be switched from
one to the other.
Note: Frequency Mode is abbreviated as FMOD.
Settings:
0 — FMOD changed by Terminal Board (Frequency Mode)
1 — FMOD (F208) (Frequency Mode)
The Frequency Mode 1 or Frequency Mode 2 selection specifies th e source of
the input frequency command signal. These selections are performed at F004
and F207, respectively.
If FMOD changed by Terminal Board is sele cted here, the ASD will follow
the control of the discrete input terminal assigned the function of Frequency
Priority. The discrete terminal Frequency Priority will toggle control to and
from Frequency Mode 1 and Frequency Mode 2 with each activation/
deactivation.
If FMOD (F208) is selected here, the ASD wil l follow the control o f the
Frequency Mode 1 setting for the durati on that the commanded frequency of
the Frequency Mode 1 setting is greater than the setting of F208.
If the commanded frequency of the Frequency Mode 1 setting is less than or
equal to the setting of F208 the ASD will follow th e setting of Frequency
Mode 2.
Direct Access Number — F200
Parameter Type — Selection List
Factory Default — FMOD (changed by
TB)
Changeable During Run — Yes
F198 F200