F721

F729

Panel Stop Pattern

Program Special Operation Panel Parameters

While operating in the Local mode this parameter determines the method used to stop the motor when the stop command is issued via the EOI.

The Decel Stop setting enables the Dynamic Braking system that is setup at F304 or the DC Injection Braking system that is setup at F250, F251, and

F252.

The Coast Stop setting allows the motor to stop at the rate allowed by the inertia of the load.

Settings:

0 — Deceleration Stop

1 — Coast Stop

Direct Access Number — F721

Parameter Type — Selection List

Factory Default — Deceleration Stop

Changeable During Run — Yes

Note: The Stop Pattern setting has no effect on the Emergency Off

settings of F603. This parameter may also be accessed by pressing the ESC key from the Frequency Command screen.

Panel Torque Command

Direct Access Number —

F725

Program Special Operation Panel Parameters

Parameter Type — Numerical

While operating using the LED Keypad Option this parameter sets the torque

Factory Default — 0.00

 

Changeable During Run — Yes

command.

 

 

 

Minimum — -250.00

 

 

Maximum — +250.00

 

 

 

 

Panel Tension Torque Bias

Direct Access Number —

F727

Program Special Operation Panel Parameters

Parameter Type — Numerical

While operating using the LED Keypad Option this parameter sets the Torque

Factory Default — 0.00

 

Changeable During Run — Yes

Bias.

 

 

 

Minimum — -250.00

 

 

Maximum — +250.00

 

 

Units — %

 

 

 

 

Panel Load Sharing Gain

Direct Access Number —

F728

Program Special Operation Panel Parameters

Parameter Type — Numerical

 

Factory Default — 100.00

 

While operating using the LED Keypad Option this parameter is used to set

the Load Sharing Gain.

Changeable During Run — Yes

Minimum — 0.00

Maximum — 250.00

Units — %

Panel Override Multiplication Gain

Program Special Operation Panel Parameters

While operating using the LED Keypad Option this parameter provides a value to be used in the event that F729 (setting) is selected for the Frequency

Override Multiplying Input (F661).

Direct Access Number — F729

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — -100.00

Maximum — 100.00

Units — %