F841 |
| F844 | |
|
| ||
Communications Option (DeviceNet/Profibus) Setting 8 | Direct Access Number — F841 | ||
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | ||
While using the DeviceNet/Profibus communications protocol, parameters | Factory Default — 0000h | ||
Changeable During Run — Yes | |||
F841 | – F846 allow the user to select the ASD memory location that holds the | ||
| |||
Command/Frequency/Monitoring instructions to be applied to the ASD for |
| ||
Communications Option Settings 8 – 13, respectively. |
| ||
See the DeviceNet Option Instruction Manual (P/N 58683) for more |
| ||
information on this parameter. |
| ||
Settings: |
| ||
0 — Disabled |
| ||
1 — FD01 (ASD Status 1) |
| ||
2 — FD00 (Output Frequency, 0.01 Hz) |
| ||
3 — FD03 (Output Current, 0.01%) |
| ||
4 — FD05 (Output Voltage, 0.01%) |
| ||
5 — FC91 (ASD Alarm) |
| ||
6 — FD22 (PID Feedback Value, 0.01 Hz) |
| ||
7 — FD06 (Input Terminal Status) |
| ||
8 — FD07 (Output Terminal Status) |
| ||
9 — FE36 (V/I Input) |
| ||
10 | — FE35 (RR Input) |
| |
11 — FE37 (RX Input) |
| ||
12 | — FD04 (Input Voltage [DC Detection], 0.01%) |
| |
13 | — FD16 |
| |
14 | — FD18 (Torque, 0.01%) |
| |
15 | — FE60 (My Monitor) |
| |
16 | — FE61 (My Monitor) |
| |
17 | — FE62 (My Monitor) |
| |
18 | — FE63 (My Monitor) |
| |
19 | — F880 (Free Notes) |
| |
20 | — FD29 (Input Power, 0.01 kW) |
| |
21 | — FD30 (Output Power, 0.01 kW) |
| |
22 | — FE14 (Cumulative Operation Time, 0.01=1 Hour) |
| |
23 | — FE40 (FM Terminal Output Monitor) |
| |
24 | — FE41 (AM Terminal Output Monitor) |
| |
|
| ||
Communications Option (DeviceNet/Profibus) Setting 9 | Direct Access Number — F842 | ||
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | ||
Same as F841. See F841 for information on this parameter | Factory Default — 0000h | ||
Changeable During Run — Yes | |||
|
| ||
|
| ||
Communications Option (DeviceNet/Profibus) Setting 10 | Direct Access Number — F843 | ||
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | ||
Same as F841. See F841 for information on this parameter | Factory Default — 0000h | ||
Changeable During Run — Yes | |||
|
| ||
|
| ||
Communications Option (DeviceNet/Profibus) Setting 11 | Direct Access Number — F844 | ||
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | ||
|
| Factory Default — 0000h |
Same as F841. See F841 for information on this parameter
Changeable During Run — Yes
H9 ASD Installation and Operation Manual | 211 |