Menu 50: Program outputs

808

Fault Finding

Menu 50: Program outputs

Menu 51: Output Types = Bell = Normally On, Strobe = Normally Off, All other NO Function

Menu 52: Internal sounder = Follows Bell

Menu 53: Bell Delay = 0, Bell Time = 20 Minutes

Menu 60: Program System Options

Menu 61: Installer information = Code = 7890

Menu 62: PA response = Audible

Menu 63: Line Fault response = Audible

Menu 64: Allow Zone omits = Disabled

Menu 65: System reset = Customer

Menu 66: Logging Printer = Disabled

Menu 67: First Circuit = Re-arm, Alarm Abort = Disabled Entry Abort = Disabled, Tampers Comms = Disabled, Set

Set No AC (Mains) = Disabled, Reset No AC (Mains) = Disabled

Alarm Confirmation = Disabled

Fault Finding

General Faults

No response from the keypad keys

Check the keypad wiring.

Check the keypad address programming.

Enter and leave programming mode.

Power up while shorting RST pins.

No exit/entry tones from remote keypad

Check keypad address programming option. (See "Keypads".)

Check keypad is assigned to the Level being set (Menu 47).

Check if keypad faulty.

Configuration Checking Error Messages

The end station checks the configuration when you exit programming mode or when you apply power. If the end station finds a configuration error during power up it displays the message "CONFIG ERROR" at the keypad. The panel is unusable until you cure the problem. (Note that this will only occur if