Return to Factory Defaults (Second stage reset)

808

Resetting Customer and Installer Codes

Resetting Customer and Installer Codes (First stage reset)

If the installer and/or user codes have been lost, or you need to return the end station to the factory default access codes, you can load the default codes as follows:

1.Disconnect mains and battery power to the system.

2.Place a small screwdriver blade between the pins marked ‘RST’ on the main PCB.

3.Apply battery and then mains power to the end station.

4.Remove screwdriver blade from RST pins after three seconds.

The system loads the factory default access codes. (1234 for User and 7890 for Installer.) All user attributes return to default values.

In addition, the system re-initialises communications with all keypads.

The remaining programming is unchanged.

Return to Factory Defaults (Second stage reset)

If you need to return the end station to factory defaults (no programming and an empty log) then:

1.Follow steps 1 to 4 in ‘Resetting Customer and Installer Codes’.

2.Reset any alarms by keying-in the default User code and pressing Enter.

3.Key-in 0 (zero) followed by the default Installer code and then press Menu.

 

The display shows:

MENU NO OR LEVEL

4.

Press 0.

 

 

The display shows:

0:INST PROG

5.

Press Enter.

 

 

The display shows:

REMOVE LID

6.Open the end station tamper switch.

The display shows:

LOAD DEFAULTS

Note: At this point you can press Menu to abort the process of loading factory defaults.

7. Press Enter.

 

The display shows:

SURE

Note: At this point you can press Menu to abort the process of loading factory defaults.

496336 Issue 1

17 of 22

Page 17