Factory Defaults
System Users UO1:

Factory Defaults

808

8. Press Enter.

 

The display shows:

LOADING DEFAULTS

Followed by:

00:PROG SYSTEM

The end station now has the full set of Scantronic factory defaults and needs reprogramming.

NOTES:

1)The Bell output will be energised. If a SAB triggers at this point then check Menu 51.

2)If you remove power during programming, and you have not created a valid configuration, then the system will force you to enter programming mode when you reapply power. To make sure you can re-enter programming mode successfully the system loads the default Installer Code.

Factory Defaults

When delivered from the factory, the 808 is preprogrammed with the follow- ing default settings:

Access Code 1234, System Full Use, Zone omit Not

Permitted, Log Access = Permitted, Change Zone names

=Permitted, Change Data and Time = Permitted, Reset

=Permitted

User 02-08: Not Used (Duress=Disabled)

User 00: Access Code = 7890

Installer programming

Menu 10: Account Name

Menu 11: Edit Name = No Name

Menu 20: Zone Type

Menu 21: Zone circuit type = CC

Menu 30: Program zones

Menu 31: Zone Names = ZO1: Zone 01 (all other zones to Zone [nnn])

Menu 32: Zone Types = All zones Not Used (NU)

Menu 40: Program multiflex

Menu 41: Level Allocation = Level A,B,C,D = None

Menu 42: Level Exit Mode = All Levels = Timed and terminate (Exit Time = 10 Seconds)

Menu 43: Level Entry Time = All Levels 20 Seconds

Menu 44: Level Flexi-Zones = Not Set Up = NU

Menu 45: Level Alarm response = All Levels = Full Alarm

Menu 46: Level Re-Arms response = All Levels = Never

Menu 47: Keypad allocation = None