F831 | F836 | |
|
| |
Communications Option (DeviceNet/Profibus) Setting 2 | Direct Access Number — F831 | |
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | |
While using the DeviceNet/Profibus communications protocol, parameters | Factory Default — 0000h | |
Changeable During Run — Yes | ||
F831 – F836 allow the user to select the ASD memory location that holds the | ||
| ||
Command/Frequency/Monitoring instructions to be applied to the ASD for |
| |
Communications Option Settings 2 – 7, respectively. |
| |
See the DeviceNet Option Instruction Manual (P/N 58683) for more |
| |
information on this parameter. |
| |
Settings: |
| |
0 — Disabled |
| |
1 — FA06 (ALCAN Command 1) |
| |
2 — FA23 (ALCAN Command 2) |
| |
3 — FA07 (ALCAN Frequency Command, 0.01 Hz) |
| |
4 — FA33 (Torque Command, 0.01%) |
| |
5 — FA50 (Terminal Output) |
| |
6 — FA51 (Analog Output Data from Comm. [FM]) |
| |
7 — FA52 (Analog Output Data from Comm. [AM]) |
| |
8 — F601 (Stall Prevention Level, %) |
| |
9 — F441 (Power Running Torque Limit 1 Level, 0.01%) |
| |
10 — F443 (Regen. Braking Torque Limit 1 Level, 0.01%) |
| |
11 — F460 (Speed Loop Proportional Gain) |
| |
12 — F461 (Speed Loop Stabilization Coefficient) |
| |
|
| |
Communications Option (DeviceNet/Profibus) Setting 3 | Direct Access Number — F832 | |
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | |
Same as F831. See F831 for information on this parameter | Factory Default — 0000h | |
Changeable During Run — Yes | ||
| ||
|
| |
Communications Option (DeviceNet/Profibus) Setting 4 | Direct Access Number — F833 | |
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | |
Same as F831. See F831 for information on this parameter | Factory Default — 0000h | |
Changeable During Run — Yes | ||
| ||
|
| |
Communications Option (DeviceNet/Profibus) Setting 5 | Direct Access Number — F834 | |
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | |
Same as F831. See F831 for information on this parameter | Factory Default — 0000h | |
Changeable During Run — Yes | ||
| ||
|
| |
Communications Option (DeviceNet/Profibus) Setting 6 | Direct Access Number — F835 | |
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | |
Same as F831. See F831 for information on this parameter | Factory Default — 0000h | |
Changeable During Run — Yes | ||
| ||
|
| |
Communications Option (DeviceNet/Profibus) Setting 7 | Direct Access Number — F836 | |
Program ⇒ Communications ⇒ Communication Settings | Parameter Type — Selection List | |
Same as F831. See F831 for information on this parameter | Factory Default — 0000h | |
Changeable During Run — Yes | ||
|
210 | H9 ASD Installation and Operation Manual |