F941

 

F945

 

 

 

Input Function Target 1

Direct Access Number —

F941

Program My Function My Function Unit 5

Parameter Type — Selection List

This parameter plays a role in the setup of the My Function feature by

Factory Default — 0 (Disabled)

Changeable During Run — Yes

selecting the functionality of the programmable Input Function Target 1

 

 

terminal.

 

 

This setting assigns the function of the programmable Input Function Target 1

 

 

terminal to any one of the user-selectable functions listed in Table 7 on pg. 240,

 

 

Table 8 on pg. 241, or Table 10 on pg. 243.

 

 

See F977 for more information on this parameter.

 

 

 

 

 

Input Function Command 1

Direct Access Number —

F942

Program My Function My Function Unit 5

Parameter Type — Selection List

This parameter is used to assign a user-selected logical operator to two user-

Factory Default — 0 (NOP)

 

 

 

selected Input Function Target variables, enable a counter/timer function, or

 

 

perform a hold/reset function.

 

 

Table 11 on pg. 245 lists the available selections. Their use and selection

 

 

requirements are described in an example at F977.

 

 

 

 

 

Input Function Target 2

Direct Access Number —

F943

Program My Function My Function Unit 5

Parameter Type — Selection List

This parameter plays a role in the setup of the My Function feature by

Factory Default — 0 (Disabled)

Changeable During Run — Yes

selecting the functionality of the programmable Input Function Target 2

 

 

terminal.

 

 

This setting assigns the function of the programmable Input Function Target 2

 

 

terminal to any one of the user-selectable functions listed in Table 7 on pg. 240,

 

 

Table 8 on pg. 241, or Table 10 on pg. 243.

 

 

See F977 for more information on this parameter.

 

 

 

 

 

Input Function Command 2

Direct Access Number —

F944

Program My Function My Function Unit 5

Parameter Type — Selection List

This parameter is used to assign a user-selected logical operator to two user-

Factory Default — 0 (NOP)

 

 

 

selected Input Function Target variables, enable a counter/timer function, or

 

 

perform a hold/reset function.

 

 

Table 11 on pg. 245 lists the available selections. Their use and selection

 

 

requirements are described in an example at F977.

 

 

 

 

 

Input Function Target 3

Direct Access Number —

F945

Program My Function My Function Unit 5

Parameter Type — Selection List

 

Factory Default — 0 (Disabled)

This parameter plays a role in the setup of the My Function feature by

Changeable During Run — Yes

selecting the functionality of the programmable Input Function Target 3 terminal.

This setting assigns the function of the programmable Input Function Target 3 terminal to any one of the user-selectable functions listed in Table 7 on pg. 240, Table 8 on pg. 241, or Table 10 on pg. 243.

See F977 for more information on this parameter.