F335

F341

Switching Load Torque During Power Running

Program Special Crane/Hoist Settings

During power running, this parameter establishes the threshold torque level that is used to determine if the Light-LoadHigh-Speed(F328) operation may engage or remain engaged if active.

If the Light-LoadHigh-Speedoperation is terminated normal operation resumes.

Note: Power running may be during forward, reverse, acceleration, or deceleration, but not during regeneration.

Direct Access Number — F335

Parameter Type — Numerical

Factory Default — 50.00

Changeable During Run — No

Minimum — -250.00

Maximum — +250.00

Units — %

Heavy-Load Torque During Power Running

Direct Access Number —

F336

Program Special Crane/Hoist Settings

Parameter Type — Numerical

During power running, this parameter establishes the threshold torque level that

Factory Default — 100.00

 

Changeable During Run — Yes

is used to determine if the Light-LoadHigh-Speed(F328) operation may

 

 

engage or remain engaged if active.

Minimum — -250.00

 

If the Light-LoadHigh-Speedoperation is terminated normal operation

Maximum — +250.00

 

 

 

resumes.

Units — %

 

 

 

 

Heavy-Load Torque During Constant Power Running

Direct Access Number —

F337

Program Special Crane/Hoist Settings

Parameter Type — Numerical

During constant power running, this parameter establishes the threshold torque

Factory Default — 50.00

 

Changeable During Run — Yes

level that is used to determine if the Light-LoadHigh-Speed(F328) operation

 

 

may engage or remain engaged if active.

Minimum — -250.00

 

If the Light-LoadHigh-Speedoperation is terminated normal operation

Maximum — +250.00

 

 

 

resumes.

Units — %

 

 

 

 

Switching Load Torque During Regenerative Braking

Direct Access Number —

F338

Program Special Crane/Hoist Settings

Parameter Type — Numerical

During regenerative braking, this parameter establishes the threshold torque

Factory Default — 50.00

 

Changeable During Run — Yes

level that is used to determine if the Light-LoadHigh-Speed(F328) operation

 

 

may engage or remain engaged if active.

Minimum — -250.00

 

If the Light-LoadHigh-Speedoperation is terminated normal operation

Maximum — +250.00

 

 

 

resumes.

Units — %

 

 

 

 

Braking Mode Selection

Direct Access Number —

F341

Program Torque Torque Control

Parameter Type — Selection List

 

Factory Default — Disabled

 

This parameter is primarily used with lifting systems to allow for enough torque

to be produced after receiving a Run command before releasing the brake. Without this feature the load would drop for a period once the brake was released.

Changeable During Run — Yes

This parameter enables this function by setting the system operating mode.

Settings:

0 — Disabled

1 — Forward Direction

2 — Reverse Direction

3 — Same Direction

142

H9 ASD Installation and Operation Manual

Page 150
Image 150
Toshiba H9 operation manual F335 F341