F442 | F446 | ||
|
|
| |
Regenerative Braking Torque Limit 1 | Direct Access Number — F442 | ||
Program ⇒ Torque ⇒ Torque Limit Settings | Parameter Type — Selection List | ||
This parameter determines the source of the Regenerative Torque Limit | Factory Default — F443 Setting | ||
Changeable During Run — Yes | |||
control signal. | |||
|
| ||
If Setting is selected, the value set at F443 is used for this parameter. |
|
| |
Settings: |
|
| |
1 — V/I |
|
| |
2 — RR |
|
| |
3 — RX |
|
| |
4 — F443 (setting) |
|
| |
|
|
| |
Regenerative Braking Torque Limit 1 Level | Direct Access Number — F443 | ||
Program ⇒ Torque ⇒ Torque Limit Settings | Parameter Type — Numerical | ||
This parameter provides a value to be used as the Regeneration Torque Limit | Factory Default — 250.0 (Disabled) | ||
Changeable During Run — Yes | |||
#1 if F443 is selected at parameter F442. | |||
|
| ||
Set this parameter to 250% to disable this function. | Minimum — 0.00 | ||
|
| ||
| Maximum — 249.9 | ||
| Units — % |
Power Running Torque Limit 2 Level
Program ⇒ Torque ⇒ Manual Torque Limit Settings
This parameter is used to set the positive torque upper limit for the #2 motor profile when multiple motors are controlled by a single drive or when a single motor is to be controlled by multiple profiles.
Direct Access Number — F444
Parameter Type — Numerical
Factory Default — 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled) Units — %
Regenerative Braking Torque Limit 2 Level
Program ⇒ Torque ⇒ Manual Torque Limit Settings
This parameter is used to set the negative torque upper limit for the #2 motor profile when multiple motors are controlled by a single drive or when a single motor is to be controlled by multiple profiles.
Direct Access Number — F445
Parameter Type — Numerical
Factory Default — 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled) Units — %
Power Running Torque Limit 3 Level
Program ⇒ Torque ⇒ Manual Torque Limit Settings
This parameter is used to set the positive torque upper limit for the #3 motor profile when multiple motors are controlled by a single drive or when a single motor is to be controlled by multiple profiles.
Direct Access Number — F446
Parameter Type — Numerical
Factory Default — 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled) Units — %
158 | H9 ASD Installation and Operation Manual |