F878

F901

 

 

Block Read Data 4

Direct Access Number — F878

Program Communications Communication Settings

Parameter Type — Selection List

This parameter plays a role in the setup of the communications network by

Factory Default — None

Changeable During Run — Yes

establishing the type of data to be read from the ASD of the communications

 

link.

 

See parameter F875 for more information on this setting.

 

 

 

Block Read Data 5

Direct Access Number — F879

Program Communications Communication Settings

Parameter Type — Selection List

This parameter plays a role in the setup of the communications network by

Factory Default — None

Changeable During Run — Yes

establishing the type of data to be read from the ASD of the communications

 

link.

 

See parameter F875 for more information on this setting.

 

 

 

Free Notes

Direct Access Number — F880

Program Communications Communication Settings

Parameter Type — Numerical

 

Factory Default — 0

This is an unused parameter that has allocated memory space.

Changeable During Run — Yes

The space may be used at the discretion of the user.This space may be used to

store information or a note to be transferred using communications.

Minimum — 0

Maximum — 65534

Network Option Reset Settings

Program Communications Communication Settings

This parameter plays a role in the setup of the communications network by establishing the targets of a Reset command received via the communications link.

Settings:

0 — Reset ASD only

1 — Reset Option Board and ASD

Direct Access Number — F899 Parameter Type — Selection List Factory Default — Reset ASD only Changeable During Run — Yes

Input Function Target 1

Direct Access Number —

F900

Program My Function My Function Unit 1

Parameter Type — Selection List

This parameter plays a role in the setup of the My Function feature by

Factory Default — 0 (Disabled)

Changeable During Run — Yes

selecting the functionality of the programmable Input Function Target 1

 

 

terminal.

 

 

This setting assigns the function of the programmable Input Function Target 1

 

 

terminal to any one of the user-selectable functions listed in Table 7 on pg. 240,

 

 

Table 8 on pg. 241, or Table 10 on pg. 243.

 

 

See F977 for more information on this parameter.

 

 

 

 

 

Input Function Command 1

Direct Access Number —

F901

Program My Function My Function Unit 1

Parameter Type — Selection List

Factory Default — 0 (NOP)

This parameter is used to assign a user-selected logical operator to two user- selected Input Function Target variables, enable a counter/timer function, or perform a hold/reset function.

Table 11 on pg. 245 lists the available selections. Their use and selection requirements are described in an example at F977.