F226

F226

RX2 (AI1) Input Point 1 Rate

Program Torque Setpoints

This parameter is used to set the gain and bias of the RX2 (AI1) input terminal when the RX2 (AI1) terminal is used as the control input while operating in the

Torque Control mode.

Note: The Expansion IO Card Option 1 option board (P/N ETB003Z)

is required to use this terminal.

RX2 (AI1) Input Torque Control Setup

Perform the following setup to allow the system to receive Torque Control input at the RX2 (AI1) input terminal:

Program Fundamental Standard Mode Selection Frequency Mode

RX2.

Program Fundamental Standard Mode Selection Command Mode Selection Terminal Block.

Provide a Run command (F and/or R).

Torque Control

Perform the following setup to allow the system to perform Torque Control from the RX2 (AI1) input terminal:

Set RX2 (AI1) Input Point 1 Rate (F226).

Set RX2 (AI1) Input Point 1 Setting (F222) — the input analog signal level that corresponds to the speed setting at RX2 (AI1) Input Point 1 Rate.

Set RX2 (AI1) Input Point 2 Rate (F227).

Set RX2 (AI1) Input Point 2 Setting (F224) — the input analog signal level that corresponds to the speed setting at RX Input Point 2 Rate.

Provide a Run command (F and/or R).

Torque Control is accomplished by establishing an associated V/f output pattern for a given RX2 (AI1) input level.

Once set, as the RX2 (AI1) input voltage changes, the ASD output speed and/or torque will vary in accordance with the above settings.

This parameter sets RX2 (AI1) Input Point 1 Rate and is the output torque value that is associated with the setting of RX2 (AI1) Input Point 1 Setting when operating in the Torque Control mode.

This value is entered as -250% to +250% of the rated torque.

See the Expansion IO Card Option 1 instruction manual (P/N 58685) for more information on the function of this terminal.

Direct Access Number — F226

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — -250.00

Maximum — +250.00

Units — %

Torque Settings

118

H9 ASD Installation and Operation Manual