BIN Input Point 1 Frequency | Direct Access Number — | F229 | |
Program ⇒ Frequency ⇒ Speed Reference Setpoints | Parameter Type — Numerical | ||
This parameter is used to set the speed of the BIN input terminals when the | Factory Default — 0.00 |
| |
Changeable During Run — Yes | |||
BIN terminals are used as the control input. | |||
|
| ||
This parameter sets BIN Input Point 1 Frequency and is the frequency that is | Minimum — 0 |
| |
Maximum — Max. Freq. (F011) | |||
associated with the setting of BIN Input Point 1 Setting. | |||
See BIN Input Point 1 Setting for further information on this setting. | Units — Hz |
| |
|
|
| |
BIN Input Point 2 Setting | Direct Access Number — | F230 | |
Program ⇒ Frequency ⇒ Speed Reference Setpoints | Parameter Type — Numerical | ||
This parameter is used to set the speed of the BIN input terminals when the | Factory Default — 100 |
| |
Changeable During Run — Yes | |||
BIN terminals are used as the control input. | |||
|
| ||
This parameter sets the BIN input signal that is associated with BIN Input | Minimum — 0 |
| |
|
| ||
Point 2 Frequency. | Maximum — 100 |
| |
This value is entered as 0% to +100% of the BIN input signal range. | Units — % |
| |
See BIN Input Point 1 Setting for further information on this setting. |
|
| |
|
|
| |
BIN Input Point 2 Frequency | Direct Access Number — | F231 | |
Program ⇒ Frequency ⇒ Speed Reference Setpoints | Parameter Type — Numerical | ||
This parameter is used to set the speed of the BIN input terminals when the | Factory Default — 60.00 |
| |
Changeable During Run — Yes | |||
BIN terminal are used as the control input. | |||
|
| ||
This parameter sets BIN Input Point 2 Frequency and is the frequency that is | Maximum — 0.00 |
| |
Maximum — Max. Freq. (F011) | |||
associated with the setting of BIN Input Point 2 Setting. | |||
See BIN Input Point 1 Setting for further information on this setting. | Units — Hz |
|
H9 ASD Installation and Operation Manual | 121 |