F410

F415

Motor Constant 1 (Torque Boost)

Program Motor Vector Motor Model

This parameter sets the primary resistance of the motor. Increasing this value can prevent a drop in the torque of the motor at low speeds. Increasing this value excessively can result in nuisance overload tripping.

Direct Access Number — F410

Parameter Type — Numerical

Factory Default — (ASD-dependent)

Changeable During Run — Yes

Minimum — 0.0

Maximum — 30.0

Units — %

Motor Constant 2 (No-load Current)

Program Motor Vector Motor Model

This parameter is used to set the current level required to excite the motor. Specifying a value that is too high for this parameter may result in hunting (erratic motor operation).

Direct Access Number — F411

Parameter Type — Numerical

Factory Default — (ASD-dependent)

Changeable During Run — No

Minimum — 10

Maximum — 90

Units — %

Motor Constant 3 (Leak Inductance)

Program Motor Vector Motor Model

This parameter is used to set the leakage inductance of the motor.

A larger setting here results in higher output torque at high speeds.

Direct Access Number — F412

Parameter Type — Numerical

Factory Default — (ASD-dependent)

Changeable During Run — Yes

Minimum — 0

Maximum — 200

Units — %

Motor Constant 4 (Rated Slip)

Program Motor Vector Motor Model

This parameter is used to set the secondary resistance of the motor.

An increase in this parameter setting results in an increase of compensation for motor slip.

Direct Access Number — F413

Parameter Type — Numerical

Factory Default — (ASD-dependent)

Changeable During Run — Yes

Minimum — 0.01

Minimum — 25.00

Units — %

Exciting Strengthening Coefficient

Program Special Special Parameters

This parameter is used to increase the magnetic flux of the motor at low-speed. This feature is useful when increased torque at low speeds is required.

Direct Access Number — F415

Parameter Type — Numerical

Factory Default — 100

Changeable During Run — Yes

Minimum — 100

Maximum — 130

Units — %

H9 ASD Installation and Operation Manual

153

Page 161
Image 161
Toshiba H9 operation manual F410 F415