Toshiba H9 operation manual F323 F329, Drooping Insensitive Torque, Drooping Output Filter

Models: H9

1 289
Download 289 pages 12.38 Kb
Page 148
Image 148

F323

F329

Drooping Insensitive Torque

Program Feedback Drooping Control

This parameter defines a torque range in which the Drooping Control settings will be ignored and the programmed torque settings will be followed.

Direct Access Number — F323

Parameter Type — Numerical

Factory Default — 10.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 100.0

Units — %

Drooping Output Filter

Program Feedback Drooping Control

This parameter is used to set the rate of output change allowed when operating in the Drooping Control mode.

Jerky operation may be reduced by increasing this setting.

Direct Access Number — F324

Parameter Type — Numerical

Factory Default — 100.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 200.0

Units — Radians/Second

Light-Load High-Speed Operation

Direct Access Number —

F328

Program Special Crane/Hoist Settings

Parameter Type — Selection List

This parameter enables the Light-LoadHigh-Speedfunction by selecting an

Factory Default — Off

 

Changeable During Run — Yes

operating mode. The Light-LoadHigh-Speedfunction accelerates the output

 

 

frequency of the ASD from the programmed speed to the setting established in

 

 

F330.

 

 

This parameter may be disabled.

 

 

Enabling the Light-LoadHigh-Speedfunction requires that an operating mode

 

 

be selected here, and that the criteria of parameters F331 F333 be met.

 

 

Settings:

 

 

0

— Off

 

 

1

— Auto Speed (F-Motor: Up, R-Generator:Down)

 

 

2

— Auto Speed (F-Generator: Down, R-Motor:Up)

 

 

3

F330 Setting (F-Motor: Up, R-Generator:Down)

 

 

4

F330 Setting (F-Generator: Down, R-Motor:Up)

 

 

 

 

 

Light-Load High-Speed Learning Function

Direct Access Number —

F329

Program Special Crane/Hoist Settings

Parameter Type — Selection List

 

 

Factory Default — Off

 

The Light-LoadHigh-Speedfunction accelerates the output frequency of the

ASD from the programmed speed to the setting established in F330 and is primarily used with Crane/Hoist functions.

Changeable During Run — No

During Light-LoadHigh-Speedoperation with this parameter enabled, parameters Panel Torque Bias (F343), Creep Frequency (F346), and the Creep Time (F347) are set to a standard set of light-load profile values. Application-specific adjustments may be required.

Note: This function should be setup with a light load only.

Settings:

0 — Off

1 — Forward/Reverse

2 — Forward Only

140

H9 ASD Installation and Operation Manual

Page 148