Emergency Off Mode Settings
Program ⇒ Protection ⇒ Emergency Off Settings
This parameter determines the method used to stop the motor in the event that an Emergency Off command is received and the system is configured to use this feature.
This setting may also be associated with the FL terminals to allow the FL relay to change states when an EOFF condition occurs by setting the FL terminal to Fault FL (all) (see F132).
Direct Access Number — F603
Parameter Type — Selection List
Factory Default — Coast Stop
Changeable During Run — No
Note: A supplemental emergency stopping system should be used with the ASD. Emergency stopping should not be a task of the ASD alone.
Settings:
0 — Coast Stop
1 — Deceleration Stop
2 — DC Injection Braking Stop
3 — Deceleration Stop (Decel #4 setting; F515)
Emergency Off DC Injection Application Time | Direct Access Number — F604 | |
Program ⇒ Protection ⇒ Emergency Off Settings | Parameter Type — Numerical | |
When DC Injection is selected at F603 this parameter determines the time that | Factory Default — 1.0 | |
Changeable During Run — Yes | ||
the DC Injection braking is applied to the motor. | ||
| ||
| Minimum — 0.0 | |
| Maximum — 20.0 | |
| Units — Seconds |
ASD Output Phase Failure Detection
Program ⇒ Protection ⇒ Phase Loss
This parameter Enables/Disables the monitoring of each phase of the
Direct Access Number — F605
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
Note: Autotune checks for phase failures regardless of this setting.
Settings:
0 — Disabled (no detection)
1 — Enabled (Run at Startup and Retry)
2 — Enabled (every Run command and Retry)
3 — Enabled (during Run)
4 — Enabled (at Startup and during Run)
5 — Enabled (detects an
H9 ASD Installation and Operation Manual | 183 |