Frymaster HD1814G, HD21814G, HD21814150G Specifications 3.3.1.1 Adjustments to Different Gas Types

Models: HD21814150G HD1814G HD21814G

1 46
Download 46 pages 28.76 Kb
Page 19
Image 19
3.3.1 Specifications

FRYMASTER HD1814 SERIES GAS FRYERS

CHAPTER 3: INSTALLATION

3.3.1 Specifications

3.3.1.1 Adjustments to Different Gas Types

Gas Adjustments

Gas Type

Natural

LP

 

 

 

Manifold Pressure†

4" W.C.*/10 mbar*

11" W.C.*/27.5 mbar*

 

 

 

Orifice Diameter

Model Specific

Model Specific

 

 

 

Burner Marking

None

None

 

 

 

Pilot Marking

26N (P/N 810-0811)

16LP (P/N 810-2400)

 

 

 

* Gas pressure may vary per fryer model and altitude. Check the rating plate for specific gas pressures.

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.

For controls and adjustments, please refer to the "gas valve" illustration on page 3-6. (Pilot Flame Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame- volume is achieved.)

Ensure that CSA propane units air shutters are adjusted to a ¼” as shown.

3-5

Page 19
Image 19
Frymaster HD1814G, HD21814G, HD21814150G operation manual Specifications 3.3.1.1 Adjustments to Different Gas Types