Control System

The gas control system is located on the right hand side of the firebox behind an access panel and the decora- tive brick panel. The fireplace is operated using only the hand held remote control unit. The system wiring diagram is shown in Figure 11. NOTE: If you choose to install either the optional battery back-up mod- ule, (Model DVTBBK), or the optional wireless wall mountable remote control, (Part #20012267), it is easier to install these at the time of fireplace instal- lation. Refer to Items #11 & #20 in the next section.

Control System Installation

1.Locate the fireplace in the desired location.

2.Remove the glass. Refer to Glass Frame Assembly Removal section.

3.If installed, remove the lava rock, volcanic rock, and- irons, embers and logs, making note of each log’s location.

4.If installed, remove the refractory brick panel right side and rear pieces.

5.Using a back-up wrench, disconnect the gas supply fitting near the right rear corner of the firebox. (Fig. 8)

Pressure Test Ports

Gas Supply Fitting

FP1793

Cover Plate

 

Fig. 8 Disconnect gas supply fitting and remove 13 screws securing the cover plate.

6.Remove pilot assembly from burner assembly by removing two (2) screws.

7.Carefully slide the burner assembly to the left out of the way, taking care not to bend or break the pilot tubes or wiring.

8.Remove 13 screws around the perimeter holding large access panel on the right hand side of the firebox.

9.Carefully pull back the panel just enough to gain ac- cess to control box.

10.Connect the gas supply to the valve. (Fig. 9) Be sure to use a back-up wrench when tightening supply fitting.

Chateau™

Gas Supply

Fitting

FP1794

Fig. 9 Connect gas supply to valve.

11.If you chose to install the optional back-up battery pack (No. DVTBBK), you must install a wall box within 15 feet (4.6 m) of the fireplace. Assemble the connectors on one end of the supplied extension wire harness to the mating connectors on the wire harness within the control box. Make sure to connect black coded wire to black and red coded wire to red.

12.The other end of the extension wire harness should be connected to the wiring of the back-up battery holder located within a wall box.

13.Insert the supplied four (4) “AA” batteries into the battery holder. Be sure to note correct polarity for each battery.

14.Mount electrical wall box containing back-up bat- teries at a convenient location with 15 feet (4.6 m) of the fireplace. Cover wall box using a blank wall plate.

15.Connect a 120V AC electrical supply to the junction box duplex outlet. Use a Romex-type strain relief connector when running wires out through the box knockout. Replace the duplex outlet and cover plate.

16.Plug the AC adaptor plug into the duplex outlet.

17.This control must now be programmed to the re- mote control transmitter(s). To program the remote control(s), make sure the 120V AC is connected and powered to the fireplace.

18.Remove the battery door on the back of the hand held remote control and install two (2) supplied “AAA” batteries. Be sure to note correct polarity. Replace battery door.

19.If you choose to install the optional wireless wall mounted remote control (Part No. 20012267), install two (2) button batteries provided with the remote control by removing four (4) screws holding the back

20011956

9

Page 9
Image 9
Vermont Casting DVT38IN installation instructions Control System Installation