Vermont Casting DVT38IN Special Feature for Cold Climates, Inside view of wireless wall switch

Models: DVT38IN

1 48
Download 48 pages 60.13 Kb
Page 10
Image 10

Chateau™

cover in place. Carefully remove the circuit board. Install batteries with dimpled side showing. (Fig.

10)Carefully replace circuit board and back cover. Tighten screws.

Install two (2)

Batteries with

Dimpled Side

Showing

FP1824

Fig. 10 Inside view of wireless wall switch.

20.Locate the learn button on the main module. (Fig.

11)Press and release the learn button using a pencil point. There will be a beep sound from the module. Then press any key on the hand-held remote control transmitter. Once the module’s internal receiver accepts the transmitter code, there will be a series of confirming beeps. If you are using the optional wall mountable remote control transmitter, press the learn button on the main module a 2nd time. There will be a beep sound from the module. Then press the ON button on the wall mountable transmitter. Once the module’s internal receiver accepts the transmitter code, there will be a series of confirming beeps.

 

Learn

 

Button

 

AUX

Learn

Junction Box

POWER

 

 

IPI

 

Continous

S

I

Pilot

ADJ.

 

Off/On Remote/Off

 

Main Module

Power Module

Main Module

FP1792

 

Fig. 11 Connect 120V AC electrical supply.

21.The fireplace remote system is now ready for use and will respond to either wireless transmitter.

22.Reassemble access panel, burner assembly, gas supply connector, brick panels, logs, embers, andirons and lava rock in reverse order of removal. (Refer to Log, Lava Rock and Ember Placement section.

23.Turn on gas supply and check that all connections are tight and leak free.

NOTE: If you need to test the inlet pressure and/or manifold pressure, there are two (2) test ports available along the right side front edge between the firebox side and outer casing. The upper test port is inlet pressure. The lower test port is manifold pressure. (Refer to Figure 8)

CAUTION: Turn off the gas supply before removing test port plug.

24.Using a 7/16” nut driver, remove the threaded plug from the test port.

25.Thread the supplied extension adaptor into the open test port.

26.Attach a 1/4” diameter pressure gauge flexible hose fully onto the barb of the adaptor.

27.Turn on gas supply and operate valve with remote control as needed to indicate gas pressure.

CAUTION: Turn off the fireplace and gas supply before removing test port adaptor and replacing plug.

28.After test, remove extension adaptor and replace plug securely.

29.Turn on gas supply and check that plugs are tight and leak free.

Special Feature for Cold Climates

This gas control system has the option of a continu- ous pilot feature. This allows the user to change from a spark to pilot system to a standing pilot system for direct vent appliances during cold climate conditions to keep the firebox warm.

When the continuous pilot mode is activated and the fireplace is turned ON, the pilot will spark and light. When the fireplace is turned OFF, the pilot will stay ON when the main burner shuts OFF.

The continuous pilot mode can be activated or de-acti- vated by the hand held remote control transmitter.

10

20011956

Page 10
Image 10
Vermont Casting DVT38IN installation instructions Special Feature for Cold Climates, Inside view of wireless wall switch