Desa Tech RFN28TD installation manual Locating Heater, Check GAS Type, Installation Items

Models: RFN28TD

1 24
Download 24 pages 58.28 Kb
Page 8
Image 8

15,000 TO 28,000 BTU/HR VENT-FREE NATURAL GAS HEATER

INSTALLATION

LOCATING HEATER

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial,

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

NOTICE: A qualified service per- son must install heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

WARNING: Maintain the mini- mum clearances shown in Figure

10.If you can, provide greater clearances from floor, ceiling, and joining wall.

You can locate heater on floor. The optional hearth base is needed. You can also install the optional decorative mantel on the heater (some mantels require hearth base).

IMPORTANT: Only use optional mantel and hearth base specified in this manual. Purchase the optional mantel and hearth base from your dealer. See Accessories, page 21.

The heater may also be mounted on a wall. You cannot use optional mantel if mounting heater on a wall.

WARNING: Never install the heater

• in a bedroom or bathroom

in a recreational vehicle

where curtains,

furniture,

 

clothing, or other

flammable

installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 5 through 7.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor.

locate heater where moving ve- hicle will not hit it.

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service.

in coldest part of room.

An optional fan kit is available from your dealer. See Accessories, page 21. If plan- ning to use fan, locate heater near an electri- cal outlet.

CEILING

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

objects are less than 36 inches

from the front, top, or sides of

the heater

• as a fireplace insert

6" Minimum From Sides Of Heater

36" Minimum

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

ground joint union

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 21.

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

Left

Right

Side

Side

Minimum To

5" Top Surface

Of Carpeting,

FLOOR

Tile or Other

Combustible

Material

Figure 10 - Mounting Clearances As Viewed From Front of Heater

8

104779

Page 8
Image 8
Desa Tech RFN28TD installation manual Locating Heater, Check GAS Type, Installation Items

RFN28TD specifications

Desa Tech RFN28TD is a notable advancement in the realm of remote communication technology, specifically designed to meet the increasing demands of modern industries. This radio frequency network device is tailored to enable seamless communication across various platforms, making it indispensable for organizations looking to enhance their operational efficiency.

One of the key features of the RFN28TD is its robust dual-band functionality, which operates across both the 2.4 GHz and 5 GHz frequency bands. This dual-band capability allows the device to adapt to varying environmental conditions, providing users with a stable and reliable connection even in congested areas. The RFN28TD is equipped with advanced adaptive transmission technology, ensuring optimal performance and quality of service by dynamically selecting the best frequency for transmission.

Another significant characteristic of the RFN28TD is its long-range communication capability. With an impressive range of up to several kilometers under optimal conditions, this device is ideal for applications requiring extensive coverage, such as industrial automation, smart cities, and agricultural monitoring. The built-in high-gain antennas further enhance its reach, allowing for improved signal penetration through obstacles.

The RFN28TD is also designed with security in mind. It incorporates advanced encryption protocols, ensuring that data transmitted over the network is secure and protected from unauthorized access. This is particularly crucial for businesses handling sensitive information, as data breaches can lead to severe consequences.

In terms of ease of use, the device offers a user-friendly interface that simplifies the setup and management processes. Its plug-and-play design allows for quick installation, making it accessible even for users with minimal technical expertise. Additionally, the RFN28TD supports a wide range of connectivity options, including Ethernet and Wi-Fi, further enhancing its versatility.

Energy efficiency is another highlight of the RFN28TD, as it operates on lower power consumption compared to traditional communication devices. This not only reduces operational costs but also contributes to a greener, more sustainable approach to technology.

In conclusion, the Desa Tech RFN28TD is a powerful and versatile communication device that combines advanced features, long-range capabilities, robust security, and energy efficiency. Its adaptability to various applications makes it an essential tool for businesses and industries aiming to leverage the benefits of modern communication technologies.