Desa Tech S26PT Inspecting Burners, Lighting Instructions, To Turn Off Gas To Appliance

Models: S26PT

1 24
Download 24 pages 15.11 Kb
Page 12
Image 12
LIGHTING

VENT-FREE PROPANE/LP PEDESTAL STOVE

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open a window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, page 11, column 3.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseTO TURN OFF GAS to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, page 11, column 3. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

THERMOSTAT CONTROLC-clockwiseto the PILOT position.

Press in control knob for five (5) sec- onds (see Figure 18).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure.

 

Ignitor Button

 

 

Control Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 18 - Control Knob and Ignitor Button Location

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

Pilot Burner

Thermocouple

Figure 19 - Pilot

MANUAL LIGHTING CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise ClockwiseINSPECTING to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise ClockwisePILOT FLAME PATTERN to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal com- fort setting will vary by household depend- ing upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the Hi setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 in column 2.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 20 shows a correct pilot flame pat- tern. Figure 21 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance)

seeTroubleshooting, pages 14 through 16

Pilot Burner

Thermocouple

Figure 20 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 21 - Incorrect Pilot Flame Pattern