CONNECTING TO GAS SUPPLY

VENT-FREE PROPANE/LP PEDESTAL STOVE

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

Back View WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

Manual background CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an ex- ternal regulator (not supplied). In- stall the external regulator between the heater and propane/LP supply.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An CSA design-certified equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connec- tion. Purchase the optional CSA design- certified equipment shutoff valve from your dealer. See Accessories, page 22.

Back View

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freezing rain or sleet.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Propane/LP

External

Supply Tank

Regulator

 

Vent

Pointing

Down

Figure 6 - External Regulator With Vent Pointing Down

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual background CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 7. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

Side View

Front Manual backgroundManual backgroundManual background of Manual backgroundManual background Stove Manual backgroundManual background Unit Manual backgroundManual background

Gas Regulator

Manual background Inlet Connection

Figure 5 - Gas Regulator Location and Gas Line Access Into Stove Cabinet

From External

 

CSA Design-Certified

Regulator (11"

 

Equipment Shutoff Valve

W.C.** to 14"

 

With 1/8" NPT Tap*

W.C. Pressure)

 

Approved

 

 

 

 

 

 

Flexible Gas

 

 

 

Hose (if allowed

 

 

 

by local codes)

 

Tee

 

 

Sediment

Joint

3" Minimum

 

Trap

Pipe

Gas

 

 

Nipple

 

Regulator

 

Cap

 

of Heater

Figure 7 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 22.

**Minimum inlet pressure for purpose of input adjustment.