Troubleshooting
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning sup- plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
Log set produces a clicking/ | 1. | Metal expanding while | 1. | This is normal with most |
ticking noise just after burners |
| heating or contracting |
| appliances. If noise is |
are lit or shut off |
| while cooling |
| excessive, contact qualified |
|
|
|
| service person |
|
|
|
|
|
Log set produces unwanted | 1. | Log set burning vapors | 1. | Open window to ventilate |
odors |
| from paint, hair spray, |
| room. Stop using odor |
|
| glues, cleaners, chemicals, |
| causing products while |
|
| new carpet, etc. (See |
| appliance is running |
|
| IMPORTANT statement |
|
|
|
| above) |
|
|
| 2. | Gas leak. See Warning | 2. | Locate and correct all leaks |
|
| statement at top of |
| (see Checking Gas Con- |
|
| page |
| nections, page 8) |
|
|
|
|
|
Gas odor even when control | 1. | Gas leak. See Warn- | 1. | Locate and correct all leaks |
knob is in OFF position |
| ing statement at top of |
| (see Checking Gas Con- |
|
| page |
| nections, page 8) |
| 2. | Control valve or gas con- | 2. | Replace control valve or |
|
| trol defective |
| gas control |
Gas odor during combustion 1. Gas leak. See Warning statement at top of page
1.Locate and correct all leaks (see Checking Gas Con- nections, page 8)
12 | www.desatech.com |