![](/images/backgrounds/46133/46133-168x1.png)
Installation
Continued
CHECKING GAS CONNECTIONS
WARNING:Testallgaspiping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Applyanoncorrosiveleakdetection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
3.Check all joints from gas meter to equip- ment shutoff valve (see Figure 6). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.
4.Correct all leaks at once.
Equipment Shutoff Valve
Gas Meter
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1.Disconnect log set with its individual equipment shutoff valve from gas supply piping system.
2.Cap off open end of gas pipe where equip- ment shutoff valve was connected.
3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
4.Check all joints of gas supply piping sys- tem. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Reconnect log set and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.Close equipment shutoff valve (see Fig- ure 5).
2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
Figure 6 - Checking Gas Joints
Hearth Kit assembly and installation
1.Determine which side the gas line will be coming into the fireplace.
NOTICE: Unit comes preassembled with gas inlet on right side. If your fireplace gas supply is on the left, gas inlet should be repositioned to left side of unit.
2.If gas supply line in your fireplace is on the right side, continue to step 3. If not, see
Repositioning the Gas Inlet to the Left Side of Unit, page 9.
3.Install adapter fitting that comes with log set into fireplace gas supply pipe (see Figure 7). Seal using thread sealant.
Adapter
Fitting
Gas
Connector
Tube
Gas Inlet
Fitting
Equipment
Shutoff
Valve
Open
Closed
Figure 7 - Connecting Adapter to Gas
Figure 5 - Equipment Shutoff Valve
Supply
www.desatech.com114370-01E