Installation
Continued
|
|
|
|
| Burner |
| Btu |
| Minimum Vent |
| |||
| Model |
|
| DESCRIPTION |
| Input |
| Opening |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 18" Ramp |
| 59,000 |
| 8" dia. |
|
| |||||
|
| 24" Ramp |
| 69,000 |
| 8" dia. |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 30" Ramp |
| 74,000 |
| 8" dia. |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| MINIMUM FIREBOX SIZES |
|
|
|
|
| |||
| MODEL |
| FRONT WIDTH | BACK WIDTH* |
| DEPTH |
| HEIGHT | |||||
|
|
|
|
|
|
|
|
|
| ||||
|
| 28" |
| 16" |
| 14" |
| 18" | |||||
|
| 29 3/4" |
| 17" |
| 15 1/2" |
| 18" | |||||
|
| 36" |
| 27" |
| 18" |
| 18" |
*At depth indicated
BURNER ORIFICE
| NATURAL | |
LOG SIZE | INCHES | NUMBER |
18" | 0.1495 | 25 |
24" | 0.1570 | 22 |
30" | 0.1660 | 19 |
FUEL INLET PRESSURE SPECIFICATIONS (W.C.)
MIN. MAX.
NG 5.5" 10.5"
Figure 2 - Technical Information Charts
VENTING SPECIFICATIONS FOR INSTALLATION
The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.
The chimney flue must remain open a minimum of 3" at all times during the operation of this log set.
Installing Damper Clamp
Secure the damper stop clamp to the edge of the damper as shown in Figure 3. If for any reason this clamp doesn't work on your fire- place, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.
Damper
Clamp
Damper
Damper
Clamp
DamperDamper
Masonry Manufactured
FireplaceFireplace
Figure 3 - Attaching Damper Clamp