DeVillbiss Air Power Company A16617 Maintenance, Engine, How To Clean The Water Inlet Filter

Models: A16617 XR2625

1 64
Download 64 pages 51.27 Kb
Page 15
Image 15
MAINTENANCE

MAINTENANCE

Risk of burn hazard. When

performing maintenance, you may be exposed to hot surfaces, water pressure or moving parts that can cause serious injury or death.

Risk of fire hazard. Always disconnect,

spark plug wire, let the engine cool and release all water pressure before performing any maintenance or repair. The engine contains flammable fuel. Do not smoke

or work near open flames while performing maintenance.

To ensure efficient operation and longer life of your pressure washer, a routine maintenance schedule should be prepared and followed. If the pressure washer is used in unusual conditions, such as high-temperatures or dusty conditions, more frequent maintenance checks will be required.

ENGINE

Consult the Engine Owners Manual for the manufacturer's recommendations for any and all maintenance. NOTE: The frame is

3.Disconnect the spray wand from the gun.

4.Remove the high-pressure nozzle from the spray wand. Remove any obstructions with the nozzle cleaning tool provided and backflush with clean water.

5.Direct water supply into spray wand to backflush loosened particles for 30 seconds.

6.Reassemble the nozzle to the wand.

7.Reconnect spray wand to gun and turn on water supply.

8.Start pressure washer and place spray wand into high pressure setting to test.

HOW TO CLEAN THE WATER INLET FILTER

This screen filter should be checked periodically and cleaned if necessary.

equipped with an oil drain hole to help make changing the engine oil easier.

PUMP

The pump on this unit is maintenance free and requires no oil, if there is a problem with the pump contact an

1.Remove filter by grasping end and removing it from water inlet of pump as shown.

Filter Screen

Authorized Service Center.

NOZZLE CLEANING

If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit supplied and the following instructions:

1.Shut off the pressure washer and turn off the water supply.

2.Pull trigger on gun handle to relieve any water pressure.

2.Clean filter by flushing it with water on both sides.

3.Re-insert filter into water inlet of pump. NOTE: Cone side faces out.

NOTE: Do not operate pressure washer without filter properly installed.

15- ENG

A16617

Page 15
Image 15
DeVillbiss Air Power Company A16617 Maintenance, Engine, How To Clean The Water Inlet Filter, Pump, Nozzle Cleaning