Speedaire Operating Instructions and Parts Manual

5Z598C

Speedaire® Portable Air Compressor

ETroubleshooting Chart

N

G

 

 

Performing repairs may expose voltage sources, moving parts, or compressed air sources.

 

 

L

 

 

Personal injury may occur. Prior to attempting any repairs unplug the power cord and bleed off

 

 

Iair pressure.

S

H

Symptom

Possible Causes

Corrective Action

Excessive tank pressure – safety valve pops off

1.Pressure switch does not shut off motor when compressor reaches "cut-out" pressure

2. Pressure switch "cut-out" too high

1.Move the pressure switch lever to the OFF position. If the outfit doesn'tshut off, and the electrical contacts are welded together, replace the pressure switch If the contacts are good, check to see if the pin in the bottom of the pressure release valve is stuck. If it does not move freely, replace the valve

2.Return the outfit to a Service Center to check and adjust, or replace switch

Air leaks at fittings

Fittings are not tight enough

Tighten fittings where air can be heard

 

 

 

escaping. Check fittings with soapy

 

 

 

water solution. DO NOT OVER-TIGHTEN

 

 

 

 

 

Air leaks at check valve

Defective or dirty check valve

Defective check valve results in a constant

 

 

 

air leak at the pressure release valve when

 

 

 

there is pressure in the tank and the

 

 

 

compressor is shut off. Remove and clean

 

 

 

or replace check valve. DO NOT OVER-

 

 

 

TIGHTEN

 

 

 

 

 

 

Air leaks at pressure switch release valve

1.

Defective pressure switch valve

1. Remove and replace the release valve

 

2.

Defective check valve

2. A defective CHECK valve results in a

 

 

 

constant air leak at the pressure release

 

 

 

valve when there is pressure in the tank

 

 

 

and the compressor is shutoff. Remove

 

 

 

and clean or replace check valve. DO

 

 

 

NOT OVER-TIGHTEN

 

 

 

 

 

Air leaks from air tank

Defective air tank

Air tank must be replaced. Do not repair

 

 

 

the leak

 

 

 

 

 

DO NOT DRILL INTO,

 

 

 

 

 

WELD, OR OTHERWISE

 

 

 

 

 

 

 

 

MODIFY AIR TANK OR IT WILL WEAKEN

 

 

 

 

 

Regulator knob – continuous air leak

Dirty or damaged regulator internal parts

Clean or replace regulator

Regulator will not shut-off air outlet

 

 

 

 

 

 

 

 

 

 

 

Pressure reading on the regulated pressure gauge drops when an accessory is used

It is normal for "some" pressure drop to occur

If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator

NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used)

6

Page 6
Image 6
DeWalt 5Z598C specifications Troubleshooting Chart, Symptom Possible Causes Corrective Action