Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches
Check Valve
Pressure Release Valve: The pressure release valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches
How to Use Your Unit
How to Stop:
1.Set the On/Auto/Off lever to "OFF".
Pressure
Release
Valve
Before Starting
Serious damage may result if the following
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
1.Make sure the On/Auto/Off lever is in the "OFF" position.
NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the quick connect.
2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)
3.Open the drain valve fully
NOTE: Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces.
4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.
5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure
6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to
The compressor is now ready for use.
13- ENG | A08184 |