ENGLISH

DEMOLITION HAMMER D25960, D25961

Congratulations!

You have chosen a DEWALT power tool. Years of experience, thorough product development and innovation make DEWALT one of the most reliable partners for professional power tool users.

Technical Data

 

 

 

D25960

D25961

 

 

 

 

Voltage

V

230

230

 

U.K. & Ireland only

V

230/115

230/115

Type

 

 

1

1

Frequency

Hz

50

50

Power input

W

1600

1600

Impact rate

min-1

1450

1450

Impact energy (EPTA 05/2009)

J

35

35

Tool holder

 

28 mm Hex

30 mm Hex

Chisel positions

 

1

1

Weight

kg

18.4

16.9

 

 

 

 

 

LPA

(sound pressure)

dB(A)

91

91

KPA

(sound pressure uncertainty)

dB(A)

3.0

3.0

LWA

(sound power)

dB(A)

102

102

KWA

(sound pressure uncertainty)

dB(A)

3.0

3.0

Vibration total values (triax vector sum) determined according to EN 60745:

Chiselling

 

 

 

Vibration emission value ah,Cheq

 

 

 

hand position:

 

 

 

one handle on main handle

 

 

 

and one hand on side handle =

m/s²

6.8

6.8

both hands on main handle =

m/s²

4.5

4.5

Uncertainty K =

m/s²

1.5

1.5

The vibration emission level given in this information

An estimation of the level of exposure to

sheet has been measured in accordance with a

vibration should also take into account

standardised test given in EN 60745 and may be

the times when the tool is switched off

used to compare one tool with another. It may be

or when it is running but not actually

used for a preliminary assessment of exposure.

doing the job. This may significantly

WARNING: The declared vibration

reduce the exposure level over the total

working period.

emission level represents the main

 

applications of the tool. However if the

Identify additional safety measures to

tool is used for different applications,

protect the operator from the effects of

with different accessories or poorly

vibration such as: maintain the tool and

maintained, the vibration emission may

the accessories, keep the hands warm,

differ. This may significantly increase the

organisation of work patterns.

exposure level over the total working

Fuses:

 

 

period.

 

 

Europe

230 V tools

10 Amperes, mains

 

 

U.K. & Ireland

230 V tools

13 Amperes, in plugs