Image 60

6 Message Reference

Value

Mnemonic

Description

0x01

None

Invalid framer ID.

 

 

 

0x02

None

Invalid message length.

 

 

 

0x03

None

Control parameters are not consistent with the type of

 

 

device being controlled or with each other.

 

 

 

6.3.4LIU Read Control Request

Synopsis:

Message sent by the application to read back the current LIU control options from the DSI SPCI Board.

Message Format:

 

 

MESSAGE HEADER

Field Name

 

Meaning

 

 

 

type

 

LIU_MSG_R_CONTROL (0x5e38)

 

 

 

id

 

liu_id

 

 

 

src

 

Sending Module ID

 

 

 

dst

 

MVD_TASK_ID (0x10)

 

 

 

rsp_req

 

used to request a confirmation

 

 

 

hclass

 

0

 

 

 

status

 

Status Response (if confirmation requested)

 

 

 

err_info

 

0

 

 

 

len

 

16

 

 

 

 

 

PARAMETER AREA

Offset

Size

Name

 

 

 

0

16

Parameter area formatted as for the LIU_MSG_CONTROL

 

 

message. The user should set the fields to zero and the

 

 

module writes the current control parameters in the

 

 

confirmation message.

 

 

 

Description:

This message is sent to the DSI SPCI Board to read back the current control parameters selected for the Line Interface Unit.

The user should always request a confirmation message. This indicates success by status of zero and contains the current control parameters in the parameter area of the message.

60

Page 60
Image 60