Digi 1 manual EN55022, European Contact, UL/CSA Safety Information

Models: 1

1 23
Download 23 pages 54.39 Kb
Page 22
Image 22

EN55022

Test

Specification

Requirement

 

EN55022

 

Radiated

Class B

Emissions

 

 

Conducted

CISPR 22

Class B

Emissions

 

 

EN 55024

Test

Specification

Requirement

 

EN55024

 

 

 

 

Electrostatic

EN61000-4-2

+2,+4 kV direct contact

Discharge

 

+2,+4 kV and +8kV air

 

 

(insulated surfaces)

 

 

+2,+4 kV(HCP&VCP)

 

 

indirect

Radiated

EN61000-4-3

3 V/m, 80Mhz-

Immunity

 

1000Mhz, amp mod

 

 

1kHz sine wave at 80%

Electrical Fast

EN61000-4-4

+0.5kV,+ 1kV (A/C)

Transient Burst

 

+0..5kV (I/O)

 

 

 

Surge

EN61000-4-5

+0.5kV,+ 1kV 1kV

 

 

 

Conducted

EN61000-4-6

3Vrms, .150Mhz to

Immunity

 

80Mhz, amp mod.

 

 

1kHz wave at 80%

Magnetic

EN61000-4-8

1 A/m Not Applicable

Immunity

 

 

 

 

 

Voltage Dips &

EN61000-4-11

>95%10ms,

Interrupts

 

30%@500ms &

 

 

>95%@5sec reduction

 

 

at rated voltage

European Contact

Digi International Joseph-von-Fraunhofer Str. 23 44227 Dortmund, GERMANY 49-231-9747-0

UL/CSA Safety Information

This device complies with the requirements of following safety standards below:

UL 1950, 3rd edition CSA No. 950

Quality Manager

Austin, Texas

October 2006

Edgeport Installation Guide (90000403 Rev. G) – Page 20

Page 22
Image 22
Digi 1 manual EN55022, European Contact, UL/CSA Safety Information