TransPort® WR44 Installation Guide
Page 14
TransPort® WR44 Installation Guide
Page 15
The TransPort WR44 also allows for dual network installations where one wireless service can be used as a
back-up in the event that the primary service fails. These installations cannot be used to access two networks
simultaneously. By default, SIM 1 is used for access to the primary network and SIM 2 is used for the back-up
network.
For added security, Digi offers a “SIM Slot Cover Plate” that can be installed on the unit to deter theft or
tampering of the SIM cards, (see the Accessories section on page 22 for more information).
Step 2) Connect the Cellular (WWAN) Antenna(s): Connect the cellular antenna to the “WWAN PRIMARY”
connector (SMA Female) on the unit. If the unit is equipped with a secondary cellular antenna connector
(WWAN SECONDARY), it is highly recommended to connect an additional antenna to this connector for
diversication. Dual antennas will provide improved signal strength thus better performance.
Note: For most applications, the antenna(s) included with the unit will provide suitable reception, but some
circumstances/environments may require a higher quality antenna or one mounted in a different location. If
this is the case, Digi has many antenna options to chose from -- please contact us or visit www.digi.com. If
antennas other than the supplied antenna(s) are used, the separation between the two should be no less than
ve inches (5”).
Step 3) (Wi-Fi models only) – Connect the Wi-Fi Antennas: Connect the Wi-Fi antennas to the ‘WIFI
PRIMARY and WIFI SECONDARY’ antenna connectors (SMA Male).
Step 4) Connect the LAN Cable: Connect one end of the Ethernet cable to the “LAN” port on the unit and the
other end to a LAN port on a PC.
Step 5) Connect the Serial Cable (optional): Connect one end of the serial cable (not included) to the
“SERIAL 0” port on the unit and other end to the serial port on a third-party serial terminal device. If you wish
to connect the unit to a PC, it is recommended that you purchase Digi’s serial cable (P/N: 76000858).
Some TransPort models also include additional serial ports which have RJ45 connectors. For those models,
Digi offers the following serial cables for connectivity:
• P/N: 76000855 -- RJ45 to DB9 Female - 6’
• P/N: 76000856 -- RJ45 to DB25 Male - 6’
• P/N: 76000857 -- RJ45 to DB25 Female - 6’
Step 6) Connect the Power Supply: Depending on model, the unit will either come with an AC power sup ply,
4-pin DC power cord, or a Fleet power cord. Instructions for all options are described below.
AC Power Supply - Connect the locking barrel end of the power supply to the “MAIN” connector on the
unit, and plug the other end into a wall outlet. “International” units come with interchangeable Power Supply
Adapters which can be used according to regional needs.
4-Pin DC Power Cord - Connect the 4-pin molded end of the cord to the “AUX” connector on the unit, and wire
the four bare wires accordingly to your needs. The red and black wires provide basic DC power input, and the
blue and green wires are programmable signal lines.
WARNING: Only one of the power connectors should be used. Never apply power to both the MAIN and AUX
ports at the same time.
Fleet Power Cord - Connect the 4-pin molded connector to the “Pwr” port on the unit. Connect the locking
barrel jack to the “MAIN” connector on the unit. Finally, wire the two bare wires accordingly to your needs.
For sample wiring diagrams and pinout information, see the 4-Pin DC Power Cord and Fleet I/O Interface User‘s
Guides, which can be found online at http://ftp1.digi.com/support/documentation/transport/technicalnotes.htm.
Step 7) When the unit is powered-up, the POWER indicator will illuminate and the unit will initiate a series of
diagnostic self-tests. During this process one or more of the other indicators will ash to show that the unit is
busy. When the ashing stops, the unit has completed its self-test diagnostics and is ready to be congured.
4 Conguration Once the unit has been installed and powered up, it needs to be congured to communicate with the LAN
and WAN. Conguration is performed either using the Command Line Interface (CLI) or the Web Interface.
The Web Interface (accessed via a web browser e.g. Firefox, IE, Chrome) is the recommended conguration
option for most users.
Note: You will not be able to use the unit for remote communication until you have subscribed to a suitable
mobile/cellular wireless network service.
4.1 Network Settings
The default IP address for the LAN port is 192.168.1.1 with a subnet mask of 255.255.255.0. The unit has a
DHCP server enabled by default which can assign an appropriate IP address to your PC if the PC is congured
to get an IP address automatically. Alternatively you can manually congure your PC to be on the 192.168.1.x
network, for example, with an IP address of 192.168.1.2 and subnet mask of 255.255.255.0. Care should be
taken to ensure that the unit does not conict with other devices that may already be on the network.
4.2 Web Interface
Step 1) Connect to the Web Interface: Open a Web browser (e.g. Firefox, IE, Chrome) on your PC and
navigate to http://192.168.1.1. If successful, you will be prompted to enter a username and password. The
default username is “username”, and the default password is “password”. After you have logged in, it is
strongly recommended that you immediately change the default username and password.
If you are unable to connect to the Web Interface, please refer to the Troubleshooting section on page 20.
Step 2) Congure the Unit: The easiest way to perform the initial conguration of the unit is by using the
Quick Start Wizard. This wizard allows you to congure the following items where applicable:
• Username and password
• LAN IP settings
• DHCP Server
• Mobile module and connection
• Wi-Fi Access Point