2.1Technical data
Voltage supply | 24 V DC (18 ... 30 V), max. current consumption for MP9000: 2.4 A |
| |
Power consumption | Max. 50 W |
| |
Connector | Input voltage connector type Phönix COMBICON, |
| |
| MSTB 2.5/ |
| |
Safety | VDE 0805 (EN 60950), VDE 0870, UL |
| |
Emissions |
| ||
Shock | 10 g / 11 ms (IEC 68) |
| |
Temperature | 5 to 50 °C (in operation) |
| |
|
| ||
Air humidity | Min. 10 % to max. 90 % (not condensing) |
| |
Enclosure | IP20; |
| |
| front of the EL series IP65 if mounted professionally |
| |
Class of protection | Class of protection 1 |
| |
Max. dimensions | See chapter 5 Dimensions and mounting space |
| |
|
|
|
|
Device type | Minimum weight of |
| |
| basic device |
|
|
MP600 | 2.4 kg |
|
|
MP1000 | 4.2 kg |
|
|
MP1000s | 4.2 kg |
|
|
MP1050 | 4.6 kg |
|
|
MP1050s | 4.6 kg |
|
|
MP2000 | 5.4 kg |
|
|
MP2050 | 5.6 kg |
|
|
MP5000 | 6.2 kg |
|
|
MP5020 | 6.4 kg |
|
|
MP5050 | 6.4 kg |
|
|
MP5070 | 7.2 kg |
|
|
MP9000 | 10.2 kg |
|
|
The monitor panel may not be used in potentially explosive atmosphere.
If the device is mounted in a separate housing, it is to be observed that the maximum ambient temperature with a peak of 45 °C (<35 °C average temperature) is not exceeded. If required, appropriate measures for passive and active cooling are to be implemented.
All information provided without warranty:
The company Lenze Digitec Controls GmbH reserves the right for changes, in particular with regard to the values, dimensions and weights specified, unless they are not noted differently.
30