Water System

Aquatic Fitness System

Troubleshooting Guide

Water System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

 

Problem

 

 

Corrective Action

 

 

 

Pulsating jets

 

Water level too low

 

 

Fill with water to 1” to 2” above bottom of

 

 

 

 

 

 

 

 

 

 

the tile line

 

 

 

No Jet Action, or action is poor

 

 

1.

HydroTherapy Jets closed

 

 

1.

Open Jets

 

 

 

 

 

2.

Diverter Valve turned

 

2.

Turn the Diverter Valve clockwise or

 

 

 

 

 

 

 

 

 

 

 

counter clockwise

 

 

 

 

 

 

3.

Dirty Filter

 

 

3.

Clean Filter

 

 

 

 

 

4.

Air lock

 

4.

Loosen pump union to allow air to

 

 

 

 

 

 

 

 

 

 

 

escape

 

 

 

 

 

 

5.

Gate valve closed

 

 

5.

Open gate valve

 

3 Flashing Lights

 

 

 

 

 

 

 

 

 

Symptom

 

Problem

 

 

Corrective Action

 

 

 

 

 

 

 

 

 

 

 

High Temperature Protection:

 

 

If the temperature fails to drop, or the

 

 

 

If the water temperature exceeds 112°F at

 

 

heater or other outputs fail to stop as

 

 

 

the Temperature Sensor, the heater and all

 

 

indicated, call the dealer.

 

 

 

other outputs will shut off.

 

 

 

 

 

 

If the water temperature exceeds 119°F at

 

 

If the temperature does not

 

 

 

 

the Hi-Limit Sensor, only the heater will be

 

 

seem to be elevated, the error

 

 

 

 

shut off. All other outputs will continue to

 

 

indication may have been

 

 

 

 

operate.

 

 

caused by poor water flow or

 

 

 

 

After the water has cooled down, power to

 

 

electrical line interference

 

 

 

 

 

 

(thunder storms, voltage

 

 

 

 

the Aquatic Fitness System must be cycled

 

 

 

 

 

 

 

 

surges, etc.) Simply reset and

 

 

 

 

on, then off, to reset the system.

 

 

 

 

 

 

 

 

monitor the system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Smart Winter Mode:

 

 

No action necessary, unless the water

 

 

 

If the system detects conditions below

 

 

temperature continues to drop and the

 

 

 

59°F, the system will automatically activate

 

 

systems fails to activate. If this happens, you

 

 

 

the Smart Winter Mode for a period of 24

 

 

should manually activate the heater and

 

 

 

hours. In this mode, if a pump has not

 

 

pumps, if freezing could be a problem, then

 

 

 

been powered up in the last two hours, the

 

 

call the dealer for service.

 

 

 

system will turn it on for one minute to

 

 

 

 

 

 

prevent freezing. The Filter Mode Light

 

 

 

 

 

 

 

 

 

 

 

 

indicator will flash while the pump is

 

 

If you notice your pumps

 

 

 

running in this mode.

 

 

coming on every 2 hours, this

 

 

 

If the spa water temperature drops below

 

 

is most likely the cause. This

 

 

 

 

 

will continue for a 24-hour

 

 

 

49°F, the pump and heater will be turned

 

 

 

 

 

 

 

period. This is normal and is

 

 

 

on for a period of 2 minutes, or until the

 

 

 

 

 

 

 

the Systems protection against

 

 

 

water reaches 50°F. All functions (except

 

 

 

 

 

 

 

freezing.

 

 

 

the alarms) will be disabled while the freeze

 

 

 

 

 

 

 

 

 

 

 

protection is active.

 

 

 

 

 

 

Temperature Sensors:

 

 

Call the dealer for service.

 

 

 

If 33°F appears constantly on the display, or

 

 

 

 

 

 

if the temperature displayed greatly differs

 

 

 

 

 

 

from the actual temperature of the water,

 

 

 

 

 

 

your temperature sensor may be in need of

 

 

 

 

 

 

service.

 

 

 

 

 

 

 

 

 

 

 

 