Aquatic Fitness System
Troubleshooting Guide
Water System
|
|
|
|
|
|
|
|
|
|
|
|
|
| Symptom |
|
| Problem |
|
| Corrective Action |
| ||
|
| Pulsating jets |
| Water level too low |
|
| Fill with water to 1” to 2” above bottom of |
| |||
|
|
|
|
|
|
|
|
| the tile line |
| |
|
| No Jet Action, or action is poor |
|
| 1. | HydroTherapy Jets closed |
|
| 1. | Open Jets |
|
|
|
|
| 2. | Diverter Valve turned |
| 2. | Turn the Diverter Valve clockwise or |
| ||
|
|
|
|
|
|
|
|
|
| counter clockwise |
|
|
|
|
|
| 3. | Dirty Filter |
|
| 3. | Clean Filter |
|
|
|
|
| 4. | Air lock |
| 4. | Loosen pump union to allow air to |
| ||
|
|
|
|
|
|
|
|
|
| escape |
|
|
|
|
|
| 5. | Gate valve closed |
|
| 5. | Open gate valve |
|
3 Flashing Lights
|
|
|
|
|
|
|
|
| Symptom |
| Problem |
|
| Corrective Action |
|
|
|
|
|
|
|
|
|
|
| High Temperature Protection: |
|
| If the temperature fails to drop, or the |
| |
|
| If the water temperature exceeds 112°F at |
|
| heater or other outputs fail to stop as |
| |
|
| the Temperature Sensor, the heater and all |
|
| indicated, call the dealer. |
| |
|
| other outputs will shut off. |
|
|
|
| |
|
| If the water temperature exceeds 119°F at |
|
| If the temperature does not |
| |
|
|
| the |
|
| seem to be elevated, the error |
|
|
|
| shut off. All other outputs will continue to |
|
| indication may have been |
|
|
|
| operate. |
|
| caused by poor water flow or |
|
|
|
| After the water has cooled down, power to |
|
| electrical line interference |
|
|
|
|
|
| (thunder storms, voltage |
| |
|
|
| the Aquatic Fitness System must be cycled |
|
|
| |
|
|
|
|
| surges, etc.) Simply reset and |
| |
|
|
| on, then off, to reset the system. |
|
|
| |
|
|
|
|
| monitor the system. |
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
| Smart Winter Mode: |
|
| No action necessary, unless the water |
| |
|
| If the system detects conditions below |
|
| temperature continues to drop and the |
| |
|
| 59°F, the system will automatically activate |
|
| systems fails to activate. If this happens, you |
| |
|
| the Smart Winter Mode for a period of 24 |
|
| should manually activate the heater and |
| |
|
| hours. In this mode, if a pump has not |
|
| pumps, if freezing could be a problem, then |
| |
|
| been powered up in the last two hours, the |
|
| call the dealer for service. |
| |
|
| system will turn it on for one minute to |
|
|
|
| |
|
| prevent freezing. The Filter Mode Light |
|
|
|
| |
|
|
|
|
|
| ||
|
| indicator will flash while the pump is |
|
| If you notice your pumps |
| |
|
| running in this mode. |
|
| coming on every 2 hours, this |
| |
|
| If the spa water temperature drops below |
|
| is most likely the cause. This |
| |
|
|
|
| will continue for a |
| ||
|
| 49°F, the pump and heater will be turned |
|
|
| ||
|
|
|
| period. This is normal and is |
| ||
|
| on for a period of 2 minutes, or until the |
|
|
| ||
|
|
|
| the Systems protection against |
| ||
|
| water reaches 50°F. All functions (except |
|
|
| ||
|
|
|
| freezing. |
| ||
|
| the alarms) will be disabled while the freeze |
|
|
| ||
|
|
|
|
|
| ||
|
| protection is active. |
|
|
|
| |
|
| Temperature Sensors: |
|
| Call the dealer for service. |
| |
|
| If 33°F appears constantly on the display, or |
|
|
|
| |
|
| if the temperature displayed greatly differs |
|
|
|
| |
|
| from the actual temperature of the water, |
|
|
|
| |
|
| your temperature sensor may be in need of |
|
|
|
| |
|
| service. |
|
|
|
| |
|
|
|
|
|
|
|
|
28