![](/images/new-backgrounds/1054381/5438121x1.webp)
Fireplace Installation
screws which hold the junction box to the fireplace chassis (Figure 6).
8.Pull the junction box and power cord out the front of the fireplace.
9.Replace removed junction box cover with the supplied
(Figure 7) and install using screws removed in steps 6
Figure 7
Hole for
Ground Screw
and 7.
10.Leaving a minimum of 3" (7.6 cm) of slack, route the power supply through the hole in the alternate junction box cover and secure with a wire clamp (not supplied).
11.Connect the black wire (live) from the unit to the black wire from the power supply using one of the wire connectors removed in step 5 (Figure 8).
12.Connect the white wire
(neutral) from the unit to the
Figure 8
Wires to
Black livecontrols wires
White neutral wires
white wire from the power supply using the second wire connector from step 5 (Figure 8).
13.Attach green grounding wire to hard wire cover cover with provided grounding screw.
Place wire
14.Reposition the electrical box cover over the wires and connectors and attach to fireplace chassis using the screw removed in step 3.
15.Carefully reinsert partially reflective glass into fireplace and anchor in place using glass brackets and screws removed in step 1.