To access the controls, go to the back of the stove. (Figure 3)
A. MAIN POWER ON/OFF SWITCH
The main power on/off switch supplies power to all stove functions (heater & flame).
B. TOP LIGHT ON/OFF SWITCH
The remote control has a range of approximately 50ft. (15.25m) it does not have to be pointed at the stove and can pass through most obstacles (including walls). It is supplied with one of 243 independent frequencies to pre- vent interference with other units. The frequency designa- tion is indicated on the back of the transmitter (Figure 4)
REMOTE CONTROL INSTALLATION
Controls the light intensity of the log bed display area. | 1. Plug stove cordset into the outlet located on the side of | |||
C. HEATER ON/OFF SWITCH |
| the receiver. (Figure 4) | ||
2. | Plug receiver into the wall outlet. | |||
The heater on off switch supplies power to the heater. | ||||
3. | Install a 9 volt battery into the transmitter. (Figure 4) | |||
D. HEATER THERMOSTAT CONTROL | ||||
! | NOTE: |
| ||
To adjust the temperature to your individual requirements, |
| |||
turn the thermostat control clockwise all the way to turn | • Stove MAIN on/off switch must be in the ON position | |||
on the heater. When the room reaches the desired tem- |
| prior to using the Remote Control. | ||
perature, turn the thermostat knob counter clockwise until | • ON/OFF Remote Control may be used to control most | |||
you hear a click. Leave in this position to maintain the |
| other electrical devices including T.V.’s, stereos and | ||
room temperature at this setting. For additional heat, turn |
| lamps. |
| |
clockwise until you hear the click again and the heater will |
| CAUTION: |
| |
turn on. |
|
| ||
• For indoor use in dry areas only | ||||
RESETTING THE TEMPERATURE CUTOFF SWITCH | ||||
• For use on electrical devices with 15 amp resistive load | ||||
Should the heater overheat, an automatic cut out will turn | ||||
| or 1/3 HP inductive load | |||
the heater off and it will not come back on without be- |
| |||
• 120 volt AC only |
| |||
ing reset. It can be reset by switching the MAIN ON/OFF |
| |||
|
|
| ||
SWITCH to OFF and waiting 5 minutes before switching |
|
|
| |
the unit back on. | Figure 4 | Receiver | ||
CAUTION: If you need to continuously reset the heater, |
|
|
| |
unplug the unit and call Dimplex North America Limited |
|
|
| |
at |
|
|
| |
Figure 3 |
|
|
| |