Dimplex EF3003-230 manual 775mmWARNING, New Wall Construction

Models: EF3003-230

1 16
Download 16 pages 48.56 Kb
Page 7
Image 7
775mmWARNING

305mm

FIGURE 3

FIGURE 4

FIGURE 5

NOTE

A 13 AMP, 230 VOLT (240V in Australia) circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is

654mm operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.

775mmWARNING

To prevent personal injury you should hire a professional to cap the chimney flue or cut a hole in the existing fireplace for wiring.

If you return your existing fireplace to its original use (Example wood burning), it should be inspected by the local building department prior to use to reduce the risk of fire and personal injury.

NEW WALL CONSTRUCTION

1.Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffic.

NOTE

The fireplace insert must be installed on a hard

surface.

2.Place the fireplace in the desired location to see how it will look in the room.

3.Mark the desired location on the floor and store the fireplace in a safe, dry and dust free location.

4.Use studs to frame an opening of 775mm wide X 654mm high X 305mm deep.

5.Plan your electrical power supply. (refer to NOTE 1)

Option #1 - The power cord can be lead from behind the trim and along the wall to an outlet near the fireplace. (FIGURE 4)

Option #2 - A new outlet can be installed inside the new frame construction. (if allowed by electrical code). (FIGURE 5)

4

Page 7
Image 7
Dimplex EF3003-230 manual 775mmWARNING, New Wall Construction