the supply and return line of the heat pump. The regulations of the trade associations must be adhered to. If in doubt, contact the manufacturers of the chemicals!

CAUTION! To prevent consequential damage it is imperative that the water circuit be neutralized after cleaning using appropriate agents.

Caution - Heating Engineers

Depending on the water quality and quantity, in particular in the case of mixed installations and plastic pipes, mineral deposits (rust sludge, lime) may form impairing the proper functioning of the heating installation. A cause of this is the water hardness as well as oxygen dissolved in the filling water as well as additional oxygen from the air which may penetrate via valves, fittings and plastic pipes (oxygen diffusion). As a preventive measure it is recommended that a physical water conditioner such as ELYSATOR be used.

CLEANING / MAINTENANCE MALFUNCTIONS / TROUBLESHOOTING DECOMMISSIONING

9 MALFUNCTIONS / TROUBLESHOOTING

This heat pump is a quality product and is designed for troublefree and maintenance-free operation. In the event that a malfunction occurs nevertheless, you will be able to correct the problem easily yourself. Simply consult the Malfunctions and Troubleshooting table in the operating manual of the controller. Malfunctions can be interrogated at the heat pump controller. If the problem cannot be corrected by the user, please contact the after-sales service in charge (see Warranty Card).

CAUTION! Any work on the heat pump may only be performed by an authorized and qualified after- sales service.

10 DECOMMISSIONING

8.3 Cleaning of Air Side

Evaporator, fan and condensate drain should be cleaned of debris (leaves, branches, etc.) from time to time. To this end, the front panel of the heat pump should be opened first at the bottom and then at the top.

10.1 Placing Out of Service in Summer

Placing the heat pump out of service in summer can be effected by switching the heat pump controller to the "Summer" operating mode.

CAUTION! Prior to opening the unit it must be ensured that all electrical circuits are disconnected from the power source.

The removal and reinstallation of the panel assemblies to be performed as described in Chapter 4.

When cleaning do not use any sharp or hard objects so as to prevent any damage to the evaporator and the condensate pan.

10.2End-of-Life Decommissioning / Disposal

Before removing the heat pump, disconnect the machine from the power supply and close all valves. Environment-relevant requirements regarding the recovery, recycling and disposal of service fuels and components in accordance with all relevant standards must be adhered to. In this context, particular attention must be paid to the proper disposal of refrigerants and refrigeration oils.

9

Page 9
Image 9
Dimplex LA16ASR Malfunctions / Troubleshooting, Decommissioning, Cleaning of Air Side, Placing Out of Service in Summer

LA16ASR specifications

The Dimplex LA16ASR is an innovative heating solution designed to deliver both efficiency and comfort in a compact form factor. This model is particularly aimed at residential users seeking effective space heating without the bulk of traditional radiators.

One of the standout features of the LA16ASR is its advanced convective heating technology. This allows for quick warming of the living space, creating a cozy environment in no time. The convection process heats air around the unit, which then rises and circulates throughout the room, providing a consistent temperature without creating cold spots. This mechanism not only enhances comfort but also optimizes energy use.

Another key characteristic of the Dimplex LA16ASR is its integrated thermostat. The built-in thermostat allows users to set their desired temperature easily, ensuring that the heater operates efficiently by maintaining the preset level. This feature minimizes energy consumption, making the unit an eco-friendly choice while also reducing utility bills.

The design of the LA16ASR is sleek and modern, making it suitable for a variety of room decors. With a compact size, it can fit seamlessly into tight spaces without compromising performance. The heater is also lightweight, making it easy to move from one room to another as needed.

Safety is paramount in HVAC systems, and the LA16ASR does not disappoint. It is equipped with overheat protection, automatically switching off the unit if it reaches excessively high temperatures. This feature provides peace of mind, particularly in homes with children or pets.

In addition to its impressive heating capabilities, the Dimplex LA16ASR is designed for quiet operation. Unlike traditional heaters that can be noisy, the LA16ASR operates without the disruptive hum, allowing for a serene environment, ideal for both homes and offices.

Finally, the LA16ASR is energy efficient and environmentally friendly. Its design and technology work together to minimize energy waste while providing immediate heat, making it an excellent investment for those looking to cut down on energy costs without sacrificing comfort.

In summary, the Dimplex LA16ASR combines effective heating technology with a modern design, safety features, and energy efficiency, making it an outstanding choice for anyone in need of a reliable heating solution.