8.2 Pump unit
As for the whole system no manual intervention is required on the pump unit when the system is operating normally. However, the pump unit offers some useful information detailing the operational status of the solar system (see Figure 57):
A:current flow rate: to be seen on flow meter
B:flow and return temperature: approximate values on flow and return ball valves
C:operating pressure: pressure gauge
D:air – separation: to be carried out on air purger without having to access the roof
A: | C: | D: |
| ||
| B: |
|
B:
Note: thermometers shown in “open” position. During normal operation the handles are to be
Figure 57 – Operational information provided by Dimplex solar pump unit SOLPU1/2
9 Maintenance
The maintenance effort for the Dimplex solar system is minimal and can ideally be exe- cuted when carrying out the mandatory checks on the unvented hot water installation. Figure 58 details the schedule of the maintenance to be carried out.
It is recommended to check the function of the system after the 1st year of operation and then carry out a
Check system pressure
The original system pressure can be found on the system commissioning sheet con- tained in the on site guide. Should the pressure have reduced considerably, the cause is to be investigated.
Check pipe work for leaks
This step is only required if the system pressure dropped considerably. Where readily accessible joints should be checked for signs of small leaks.