Dimplex XL6N Installation Instructions, Fixing Assembly, Preparation, Suggested Fixings, Earth

Models: XLS6N XL6N

1 4
Download 4 pages 12.14 Kb
Page 2
Image 2
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

PREPARATION

The heater will arrive separately from its storage bricks, 4 bricks will be required.

(2 Packs) Catalogue No. XT8300

WARNING - This appliance must be earthed

Only heat resisting cable (min. rating T85) should be used. The wires in the mains cable will be coloured as follows:-

GREEN & YELLOW

-

EARTH
BLUE

-

NEUTRAL

BROWN

-

LIVE

SUGGESTED FIXINGS

SOLID BRICK/BLOCK: No. 10 Rawlplug fibre inserts, 5.5mm drill bit. Drill hole 6mm deeper than rawlplug length.

3. XLS6N MODEL ONLY - The Room Sensor is located at the rear of the right hand side of the heater. Remove sensor from plate, carefully slide the sensor plate down from its transit

position to its operational position. Refit sensor to plate.

3.

4. Place the heater on its feet and in the desired position against the wall. Ensure the heater is based on a firm level surface at least 75mm from any end wall and at least 250mm below any shelf or similar projection. Cut away any gripper rod or carpet which would prevent the heater sitting

firmly on the floor.

4.

5. Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall.

Remove the wall bracket from the heater by removing the screw at each end. Place the heater to one side and reposition the bracket against the wall using the corner marks for alignment.

Four fixing positions must be chosen for this heater. Mark the positions for the fixing holes - one at each end. Remove the bracket from the wall, drill the holes in the positions marked, and insert suitable fixings previously described. Secure the wall bracket to the wall.

PLASTERBOARD - If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable.

NOTE: FOR OTHER WALL TYPES (e.g. Timber frame and hollow concrete) SEEK SPECIALIST ADVICE.

FIXING ASSEMBLY

1. ENSURE THAT FIXING KIT AND FEET HAVE BEEN LOCATED BEFORE DISPOSING OF PACKAGING.

2. Fit the feet with the open end of the foot to the front of the heater. Secure each foot using two taptite screws provided in the fixing kit.

2.

5.

6. If mains connection is to be made from the left side, at this point the mains lead must be secured to the back of

the heater using ties provided in the fixing kit.

6.

Page 2
Image 2
Dimplex XL6N Installation Instructions, Fixing Assembly, Preparation, Suggested Fixings, Packs Catalogue No. XT8300, Earth