SERVICE AND MAINTENANCE

Caring For Hoses

1.Inspect hoses before each use. If hoses have excessive wear, tears, or punctures, replace immediately.

2.To prolong the life of the hose, periodically rotate hose and turn hose end to end. Refer to Preventative Maintenance Schedule in this manual.

3.Avoid twists and sharp turns in the hoses, as they will increase wear on the hoses.

4.Avoid dragging the lower hose along the sides of buildings or other hard surfaces.

Cleaning Poly Mesh

The poly mesh on the collection system is located inside the container hood. For best results, clean poly mesh regularly.

DO NOT USE THE COLLECTION SYSTEM WITHOUT POLY MESH SECURELY IN PLACE.

Troubleshooting Guide

DANGER

Before servicing unit, wait for all moving parts to come to a complete stop. Turn engine off and remove the spark plug wire.

PROBLEM

POSSIBLE CAUSE

CORRECTION

Loss of Vacuum.

Blower, hose or hood inlet clogged.

Remove hose and clean inlet.

 

Hopper full.

Inspect and empty.

 

Fan blades bent or broken.

Replace/repair impeller.

 

Poly mesh plugged.

Clean poly mesh.

 

 

 

Unusual vibration

Solid object jammed in unit.

Check and remove any

or noise

 

obstruction.

 

Loose or missing bolts on unit.

Tighten or replace bolts.

 

Bent or damaged fan.

Replace/repair impeller.

 

 

 

Unit difficult to close.

Obstructions keeping door

Clear obstructions.

 

from completely closing.

 

 

Hood hinge bolts too tight.

Loosen bolts.

 

 

 

 

 

 