Dixon ZTR 5023, ZTR 5425 manual Electrical System, Troubleshooting

Models: ZTR 5425 ZTR 5023

1 49
Download 49 pages 42.5 Kb
Page 46
Image 46
ELECTRICAL SYSTEM:

TROUBLESHOOTING

ELECTRICAL SYSTEM:

SITUATION

CAUSES

REMEDY

Starter will not

Circuit breaker

Push button to reset

turn engine over

disengaged

Consult your dealer for repair

 

 

 

Starter will not

Dead battery

Charge battery

turn engine over

 

 

 

 

 

Battery discharge

Poor battery connections

Tighten or replace as required

 

Battery water low

 

 

Wrong battery installed

 

 

in mower

 

 

 

 

Battery discharge

Engine electrical system

Have electrical system checked by

 

not functioning correctly

your dealer

 

 

 

Battery discharge

Engine being operated

Increase engine RPM

 

at too low an RPM

Contact your dealer for information

 

 

 

NOTE: Electrical system failures are generally simple in nature, always check the obvious first and then move onto the more complicated parts used. Poor battery service, loose connections, corrosion, frayed or broken wiring, are more likely than component failure.